Read Sharp XG-PH50X (serv.man21) Technical Bulletin online

PJR 2006 04 02
Date of Issue:             15
th
 April 2006
        
Classification:
White
PROJECTOR TECHNICAL BULLETIN
Page 1 of 2
Sharp Electronics (UK) Limited
Reference - LP-008
Revision  - 1
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
 Red – Carry out on all units
MODEL
XGPH50X-NLK
SYMPTOM Unit shuts down due to temperature sensor mis-operation.
CAUSE
Software.
ACTION
If the firmware version is 1.20 or less, then change the temperature sensor operating
threshold.  This is achieved by adjusting the data in the EEPROM as follows:  
Note
•  This software has been updated from serial number 603 411193.
•  To check the current firmware, refer to the Status Screen Menu.  Refer to the
'Overview of All Menu Settings' in the Operation Manual.
1.  Enter the adjustment process mode.
2.  With remote control, push the following keys in order of: “ON”, “VOL UP”, “VOL
DOWN”, “VOL UP”, “VOL DOWN”, “ENTER”, “ENTER” and “MENU”.
3.  Enter “SPECIAL”.
A/D
DLP
DLPV
VIDEO
COMPO
LINE
SSS
PATTERN
CVIC
SPECIAL
FIRMWARE
NETWORK
EXIT
4.  Enter “E2PROM”.
IPL
IPL2
E2PROM
ADR RD/WR
ADR-H 1
ADR-L 32
DATA 8
PJR 2006 04 02
Date of Issue:             15
th
 April 2006
        
Classification:
White
PROJECTOR TECHNICAL BULLETIN
Page 2 of 2
Sharp Electronics (UK) Limited
Reference - LP-008
Revision  - 1
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
 Red – Carry out on all units
5.  Adjust the values as shown in the right table.
6.  Change the value of “ADR-H” to 3.
7.  Change the value of “ADR-L” to 27.
8.  At this time, the value of “DATA” is 30. Change it to 36.
9.  Change the value of “ADR-L” to 28.
10. At this time, the value of “DATA” is 30. Change it to 36.
11. Repeat the same procedure from 4-4 to 4-5 for “ADR-L”, 29, 30, 31 and 32.
ADR-H
ADR-L
DATA
3
27
36
3
28
36
3
29
36
3
30
36
3
31
36
3
32
36
12. Exit the adjustment process mode.
13. With remote control, push “UNDO” 2 times. The screen will return to the top menu
of the adjustment process mode. 
14. Exit the adjustment process mode.
A/D
DLP
DLPV
VIDEO
COMPO
LINE
SSS
PATTERN
CVIC
SPECIAL
FIRMWARE
NETWORK
EXIT
15. Turn the power of the projector off, and then pull out the AC cord from the
projector.
16. By pulling out the AC cord from the projector after turning the power off, the
changed values become effective.
Page of 2
Display

Download Sharp XG-PH50X (serv.man21) Technical Bulletin

Here you can read online and download Sharp XG-PH50X (serv.man21) Technical Bulletin in PDF. XG-PH50X (serv.man21) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp XG-PH50X (serv.man21) Projector. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.