XG-PH50X
XG-PH50X-NL
In the interests of user-safety (Required by safety regulations in some countries) the set should be re-
stored to its original condition and only parts identical to those specified should be used.
MODELS
MODELLE
XG-PH50X
XG-PH50X-NL
MULTIMEDIA
-
PROJECTOR
MULTIMEDIA-PROJEKTOR
Im lnteresse der Benutzersicherheit (erforderliche Sicherheitsregeln in einigen Ländern) muß das Gerät in seinen
Originalzustand  gebracht werden.  Außerdem dürfen für die spezifizierten Bauteile nur identische Teile verwendet
werden.
SERVICE MANUAL
SERVICE-ANLEITUNG
SHARP CORPORATION
S35G5XG-PH50X
2
XG-PH50X
XG-PH50X-NL
CONTENTS
Page
Page
INHALT
Seite
Seite
• SPECIFICATIONS ............................................ 3
• IMPORTANT SERVICE SAFETY
NOTES (for USA) .............................................. 4
• NOTE TO SERVICE PERSONNEL .................. 6
• OPERATION MANUAL ................................... 10
• DIMENSIONS ................................................. 17
• REMOVING OF MAJOR PARTS .................... 18
• RESETTING THE TOTAL LAMP TIMER ........ 31
• ELECTRICAL ADJUSTMENT ......................... 33
• TROUBLESHOOTING TABLE ........................ 42
• CHASSIS LAYOUT ....................................... 134
• BLOCK DIAGRAM ........................................ 136
• OVERALL WIRING DIAGRAM ..................... 138
• WAVEFORMS ............................................... 140
• PRINTED WIRING BOARD ASSEMBLIES .. 141
• PARTS LIST
Ë 
ELECTRICAL PARTS ............................... 156
Ë 
CABINET AND MECHANICAL PARTS .... 180
Ë
  ACCESSORIES PARTS ........................... 185
Ë
  PACKING PARTS ..................................... 185
• PACKING OF THE SET ................................ 186
• SCHEMATIC DIAGRAM ........................ D1-D71
• SPEZIFIKATIONEN ........................................ 70
• HINWEISE FÜR DAS
WARTUNGSPERSONAL ................................ 71
• BEDIENUNGSANLEITUNG ............................ 73
• ABMESSUNGEN ............................................ 80
• ENTFERNEN DER HAUPTTEILE .................. 81
• RÜCKSTELLEN DES
LAMPENBETRIEBSZEIT-TIMERS ................. 94
• ELEKTRISCHE EINSTELLUNG ..................... 96
• FEHLERSUCHTABELLE .............................. 105
• CHASSIS-ANORDNUNG ............................. 134
• BLOCKSCHALTBILD .................................... 136
• GESAMTSCHALTPLAN ................................ 138
• WELLENFORMEN ........................................ 140
• LEITERPLATTENEINHEITEN ...................... 141
• ERSATZTEILLISTE
Ë
 ELEKTRISCHE BAUTEILE ....................... 156
Ë
 GEHÄUSE UND MECHANISCHE
    BAUTEILE ................................................. 180
Ë
 ZUBEHÖRTEILE ....................................... 185
Ë
 VERPACKUNGSTEILE ............................. 185
• VERPACKEN DES GERÄTS ........................ 186
• SCHEMATISCHER SCHALTPLAN ........ D1-D71
3
XG-PH50X
XG-PH50X-NL
Product type
Multimedia Projector
Model
XG-PH50X (standard zoom lens attached)/XG-PH50X-NL (no lens attached)
Video system
NTSC3.58/NTSC4.43/PAL/PAL-M/PAL-N/PAL-60/SECAM/
DTV480I/DTV480P/DTV540P/DTV576I/DTV576P/DTV720P/DTV1035I/DTV1080I
Display method
Single Chip Digital Micromirror Device
TM
 (DMD
TM
) by Texas Instruments
DMD panel
Panel size: 0.7"
No. of dots: 786,432 dots (1,024 [H] 
✕ 
768 [V])
Lens
1.2 
 electric zoom/focus lens, F1.8–F2.0, f = 25.6–31.3 mm (standard equipment with XG-PH50X)
Projection lamp
250 W 
✕ 
2
Component input (INPUT 1)/
15-pin mini D-sub connector
output (OUTPUT) signal
Y: 1.0 Vp-p, sync negative, 75 
 terminated
PB: 0.7 Vp-p, 75 
 terminated
PR: 0.7 Vp-p, 75 
 terminated
Horizontal resolution
750 TV lines (DTV720P)
Component input (INPUT 2)
BNC connector
signal
Y: 1.0 Vp-p, sync negative, 75 
 terminated
PB: 0.7 Vp-p, 75 
 terminated
PR: 0.7 Vp-p, 75 
 terminated
RGB input (INPUT 1/2)/
15-pin mini D-sub connector, 5 BNC connector
output (OUTPUT) signal
RGB separate/sync on green type analog input: 0–0.7 Vp-p, positive, 75 
 terminated
HORIZONTAL SYNC. SIGNAL: TTL level (positive/negative)
VERTICAL SYNC. SIGNAL: Same as above
RGB digital input signal (INPUT 3) DVI connector (24-pin), RGB (digital), 250 –1,000 mV, 50
 
 
(Compatible with HDCP)
Video input signal
RCA connector: VIDEO, composite video, 1.0 Vp-p, sync negative, 75 
 terminated
(INPUT 4)
S-video input signal
4-pin mini DIN connector
(INPUT 5)
Y (luminance signal): 1.0 Vp-p, sync negative, 75 
 terminated
C (chrominance signal): Burst 0.286 Vp-p, 75 
 terminated
Audio input signal
ø3.5 mm stereo minijack: AUDIO, 0.5 Vrms, more than 22 k
Audio output signal
ø3.5 mm minijack
(AUDIO OUTPUT 1–5)
0.5 Vrms, less than 2.2 k
RS-232C terminal
9-pin mini DIN connector
LAN terminal
8-pin RJ-45 modular connector
Pixel clock
12–230 MHz
Vertical frequency
43–200 Hz
Horizontal frequency
15–126 kHz
Audio output
3.0 W (stereo)
Speaker system
4.5 cm round
 
✕ 
2
Rated voltage
AC 100–240 V
Input current
6.3 A (AC 100 V)–2.6 A (AC 240 V)
Rated frequency
50/60 Hz
Power consumption
630 W (when 
"
Eco Mode
"
 is 
"
OFF
"
)/505 W (when 
"
Eco Mode
"
 is 
"
ON
"
) with AC 100 V
600 W (when 
"
Eco Mode
"
 is 
"
OFF
"
)/485 W (when 
"
Eco Mode
"
 is 
"
ON
"
) with AC 240 V
Power consumption (standby)
0.75 W (AC 100 V) – 1.25 W (AC 240 V) (When 
"
Monitor Out
"
 and 
"
LAN/RS232C
"
 are set to 
"
Disable
"
.)
Heat dissipation
2,370 BTU/hour (when 
"
Eco Mode
"
 is 
"
OFF
"
)/1,900 BTU/hour (when 
"
Eco Mode
"
 is 
"
ON
"
) with AC 100 V
2,260 BTU/hour (when 
"
Eco Mode
"
 is 
"
OFF
"
)/1,825 BTU/hour (when 
"
Eco Mode
"
 is 
"
ON
"
) with AC 240 V
Operating temperature
41°F to 104°F (+5°C to +40°C)
Storage temperature
–4°F to 140°F (–20°C to +60°C)
Cabinet
Plastic
I/R carrier frequency
38 kHz
Dimensions (approx.)
16 
5
/
32
 7 
3
/
32
 18 
35
/
64
" (410 (W) 
 180 (H) 
 471 (D) mm) (main body only)
16 
5
/
32
 7 
37
/
64
 18 
35
/
64
" (410 (W) 
 192.1 (H) 
 471 (D) mm) (including adjustment foot and projecting
parts)
Weight (approx.)
XG-PH50X: 32.7 lbs. (14.8 kg), XG-PH50X-NL: 30.0 lbs. (13.6 kg)
Replacement parts
Lamp unit (AN-PH50LP1/AN-PH50LP2), Remote control (9NK5041808700), Power cord for U.S., Canada,
etc. (9NK3090152800), Power cord for Europe, except U.K. (9NK3090152700), Power cord for U.K., Hong
Kong and Singapore (9NK3090152900), Power cord for Australia, New Zealand and Oceania (9NK3090152600),
RGB cable (9NK3080431000), Remote mouse receiver (9NK3790197000), Cap for the standard zoom lens
(9NK3797200400), Projector manual and technical reference CD-ROM (9NK3532094500), Operation manual
(9NK5010011800)
As a part of policy of continuous improvement, SHARP reserves the right to make design and
specification changes for product improvement without prior notice. The performance specifica-
tion figures indicated are nominal values of production units. There may be some deviations from
these values in individual units.
SPECIFICATIONS
4
XG-PH50X
XG-PH50X-NL
IMPORTANT SERVICE SAFETY NOTES (for USA)
Ë
Service work should be performed only by qualified service technicians who are
thoroughly familiar with all safety checks and servicing guidelines as follows:
WARNING
1. For continued safety,  no modification of any circuit
should be attempted.
2. Disconnect AC power before servicing.
BEFORE RETURNING THE PROJECTOR:
(Fire & Shock Hazard)
Before returning the projector to the user,  perform
the following safety checks:
1. Inspect lead wires are not pinched between the chassis
and other metal parts of the projector.
2. Inspect all protective devices such as non-metallic
control knobs, insulating materials, cabinet backs,
adjustment and compartment covers or shields,
isolation resistor-capacity networks, mechanical
insulators, etc.
3. To be sure that no shock hazard exists, check for
current leakage in the following manner:
»
Plug the AC cord directly into a 120-volt AC outlet,  (Do
not use an isolation transformer for this test).
»
Using two clip leads, connect a 1.5k ohm, 10 watt
resistor paralleled by a 0.15µF capacitor in parallel
between all exposed metal cabinet parts and earth
ground.
»
Use an AC voltmeter with sensitivity of 5000 ohm per
volt.,  or higher,  sensitivity to measure the AC voltage
drop across the resistor (See Diagram).
»
All checks must be repeated with the AC plug
connection reversed.  (If necessary,  a non-polarized
adapter plug must be used only for the purpose of
completing these checks.)
Any reading of 0.3 volts RMS (this corresponds to 0.2
milliamp. AC.) or more is excessive and indicates a
potential shock hazard which must be corrected before
returning the unit to the owner.
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
SAFETY NOTICE
Many electrical  and  mechanical parts in DMD™
Projector have special safety-related characteristics.
These characteristics are often not evident from visual
inspection, nor can protection afforded by them be
necessarily increased by using replacement components
rated for higher voltage, wattage, etc.
Replacement parts which have these special safety
characteristics are identified in this manual; electrical
components having such features are identified  by “
å
and  shaded  areas in the Replacement Parts Lists and
Schematic Diagrams.  For continued protection,
replacement parts must be identical to those used in
the original circuit.  The use of a substitute replacement
parts which do not have the same safety characteristics
as the factory recommended replacement parts shown
in this service manual, may create shock,  fire or other
hazards.
AVIS POUR LA SECURITE
De nombreuses pièces, électriques et mécaniques, dans
les projecteur à DMD™ présentent des caractéristiques
spéciales relatives à la sécurité,  qui ne sont souvent pas
évidentes à vue.
Le degré de protection ne peut pas être nécessairement
augmentée en utilisant des pièces de remplacement
étalonnées pour haute tension, puissance,  etc.
Les pièces de remplacement qui présentent ces
caractéristiques sont identifiées dans ce manuel;
les pièces électriques qui présentent ces particularités
sont identifiées par la marque “
å
” et hachurées dans la
liste des pièces de remplacement et les diagrammes
schématiques.  Pour assurer la protection, ces pièces
doivent être identiques à  celles  utilisées dans le circuit
d’origine.  L’utilisation de pièces qui n’ont pas les mêmes
caractéristiques que les pièces recommandées par l’usine,
indiquées dans ce manuel, peut provoquer des
électrocutions, incendies ou autres accidents.
WARNING: The bimetallic component has the primary
conductive side exposed. Be very careful in
handling this component when the power is on.
AVERTISSEMENT: La composante bimétallique dispose du
conducteur primaire dénudé. Faire attention
lors de la manipulation de cette
composante sous tension.
DVM
AC SCALE
1.5k ohm
10W
TO EXPOSED
METAL PARTS
CONNECT TO
KNOWN EARTH
GROUND
0.15 µF
TEST PROBE
Page of 127
Display

Download Sharp XG-PH50X (serv.man15) Service Manual (Repair Manual)

Here you can read online and download Sharp XG-PH50X (serv.man15) Service Manual in PDF. XG-PH50X (serv.man15) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp XG-PH50X (serv.man15) Projector. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.