3. Removing the PWB Units
3-1. Remove the four screws from the output unit and disconnect the color wheel unit connector (J501).
3-2. Disconnect the output unit from the PC I/F unit connector. Tilt this unit toward the optical mechanism unit.
3-3. Remove the four screws from the main unit and detach the cooling fan (intake). Disconnect the S-out unit
connector (AU) and the temperature ensor connector (TI). Now take out the main unit.
3-4. Remove the two spacers, the screw and all the connectors from the S-out unit. Detach the S-out unit.
3-5. Remove the six spacers, the two screws and all the connectors from the PC I/F unit. Pull up and off the PC I/
F unit and the terminal unit together.
3-6. Detach the insulation barrier from the PC I/F unit.
3-7. Remove the four spacers and the two screws from the shielded board. Detach the shielded board.
3-8. Detach the insulation barrier from the power/ballast unit.