XG-NV6XE (serv.man4). Service Instructions Troubleshooting - Sharp Projector Service Manual (repair manual). Page 14

Read Sharp XG-NV6XE (serv.man4) Service Manual online

14
XG-NV6XE
4. Removing the PWB units
4-1. Remove the five lock screws off the PC I/F unit. Lift and detach the unit off the output unit.
4-2. Disconnect the connectors from the output unit.
4-3. Remove the four lock screws off the output units. Remove also the lock screw off the ground fixture and
detach the ground fixture. Lift and detach the output, terminal and signal units.
(FD)
(IR)
(F)
(AZ)
(FE)
(EA)
(RP)
(BP)
(RI) (D)(Q)(L) (FA)(SO)(FB)
(GP)
4-1
4-2
4-3
4-3
PC I/F Unit
Terminal Unit
Signal Unit
Bottom Cabinet
Ground Fixture
Output Unit
Optical Mechanism Unit
Output Unit