30
Troubleshooting
Unable to transfer images or an error occurs with communication
H
Check that the connection type is surely selected as you intend
(page 18)
.
In case of infrared communications (IrCOM)
H
Check that the infrared ports (the projector and the PC) are within
1 metre (3 feet) distance and keep the vertical and horizontal range
within 30 degrees
1 metre (3 feet) distance and keep the vertical and horizontal range
within 30 degrees
(page 6)
.
H
Check that there are no obstacles between the projector and the
PC.
PC.
H
Avoid using this function under strong lighting conditions.
Strong light sources such as sunlight or fluorescent lighting may
interfere with image transmissions.
Strong light sources such as sunlight or fluorescent lighting may
interfere with image transmissions.
H
Check that the projector is in the IrCOM mode before transferring
images from the PC. (See the projector operation manual.)
The On-screen Display “IrCOM stand by” or “IrCOM stand by
Waiting for Data” will appear on the projection screen.
images from the PC. (See the projector operation manual.)
The On-screen Display “IrCOM stand by” or “IrCOM stand by
Waiting for Data” will appear on the projection screen.
H
Check that your PC’s IrDA port is activated and configured properly.
Check the PC’s instruction manual.
Check the PC’s instruction manual.
H
Check that “Wireless (IrCOM)” is selected in the “File” menu
(page 18)
.
H
Confirm that the port for infrared communications is correctly specified
in the PC’s settings
in the PC’s settings
(page 13)
.
H
For Windows 95 users: Check that Microsoft’s IrDA 2.0 (Infrared
Driver) is installed
Driver) is installed
(page 5)
.
H
Check that the display mode is appropreate for the images. (Normal
transfer: 24 bit colour or less; “startup Image” transfer: 256 colours
for BMP files)
transfer: 24 bit colour or less; “startup Image” transfer: 256 colours
for BMP files)
In case of cable communications (RS-232C)
H
Check that the port for the RS-232C serial cable is correctly specified
in the PC’s settings
in the PC’s settings
(page 18)
.
H
Check that the cable is correctly and securely connected
(page 7)
.
“Gamma Correction” is not operating properly
H
Reconnect the RS-232C serial cable and try again.
The cable may not be connected properly or an error may have
occurred during the transmission.
The cable may not be connected properly or an error may have
occurred during the transmission.
H
Check that the port for serial (RS-232C) communications is correctly
specified in the PC’s settings
specified in the PC’s settings
(page 18)
.