XG-NV5XE (serv.man40). 43 - Sharp Projector Service Manual (repair manual). Page 2

Read Sharp XG-NV5XE (serv.man40) Service Manual online

30
XG-NV5XE
XG-NV5XM
TROUBLE SHOOTING TABLE 
(Continued)
Checking the video unit circuit    
Yes
No
Check the IC6001 selector switch, 
terminal voltage and input circuit.
Yes
No
Is there video signal input at IC6004?
Check the low-pass and buffer 
circuits of Q6009 thru Q6015.
Yes
No
Are there signal outputs at pins (6) 
and (8) of IC6004?
Check IC6004 and its peripheral 
circuits (bias).
Yes
No
Check the low-pass and buffer circuits 
of Q6002 thru Q6008. Is the signal as 
specified?
Go to "Checking IC801 (RGB signal 
output circuit)".
Is there video signal output at pin (7) 
of IC6001?
Check Q6002 thru Q6008 and their 
peripheral circuits.
Checking the video system
Yes
No
Go to "Lamp fails to light-up".
Yes
No
Is specified voltage fed to EA  
connectors?
Check the power circuit and its parts.
Yes
No
Are there signal inputs at pins (3) and 
(29) of P402?
Are there signals at pin (4) of IC401 
and pin (4) of IC402?
Are there signal outputs at pins (3) 
and (6) of IC816?
Yes
Check the video unit circuit 
(IC6004 and its  peripheral 
circuits).
No
Check the oscillation circuit 
of IC401 and IC402, and 
their peripheral circuits.
Yes
Go to "Checking IC801 
(RGB signal output circuit)".
No
Check IC816, IC806 and 
their peripheral circuits as 
well as switching circuit.
Is the lamp on?
Page of 15
Display