Read Sharp XG-NV51XE (serv.man11) Service Manual online
37
XG-NV51XE/XM/XA
Checkig the Power Unit
There is no voltage output at
EA connector.
EA connector.
Yes
No
No
No
No
No
Yes
Yes
Yes
Yes
Is there any other output
voltage failure?
voltage failure?
Is EA connector disconnected
or loose?
or loose?
Is AC voltage (85-264V)
applied across the PA
connector?
applied across the PA
connector?
Is Q704 open?
Is there short-circuit between
collector and emitter of Q752?
collector and emitter of Q752?
Reconnect the EA connector.
Replace F701.
Which output voltage line fails?
Replace ICP751.
Replace R752.
Replace Q752.
Replace PC702.
Replace IC702, T701 or Q704.
P-FAN Vcc
-7
TROUBLE SHOOTING TABLE
(Continued)
Click on the first or last page to see other XG-NV51XE (serv.man11) service manuals if exist.