XG-C55X (serv.man34). Sound is output for a moment at maximum volume level when the projector is turned ON - Sharp Projector Technical Bulletin (repair manual). Page 3

Read Sharp XG-C55X (serv.man34) Technical Bulletin online

LV-097
Sharp Electronics (UK) Ltd., Technical Services Group
3-3. Make sure that the ERR is returned from the projector when you pressed ENTER key.
4. Call the process mode. Press the operation keys in this order:
POWER ON / ADJ UP / ADJ DOWN / ADJ UP / ADJ DOWN / ENTER / ENTER / MENU
5. Select the SPECIAL on the process menu and then press ENTER key.
6. Select the IPL2 on the sub menu and then press ENTER key.
The lamp will turns off and the projector goes into the software writing mode.
7. Once unplug the AC cord and then plug it in again.
Note: Be sure to unplug the AC cord once and plug it in again, at this step.
8. On the Tera Term Pro, enter the RATE1152 and then press ENTER key.
9. On the Tera Term Pro, select the Setup and then the Terminal.
Click the Local echo to uncheck and then click the OK button.
Page of 5