XG-C55X (serv.man29) - Sharp Projector User Guide / Operation Manual. Page 90

Read Sharp XG-C55X (serv.man29) User Guide / Operation Manual online

Lamp
unit
BQC-XGC55X//1
User service screw
Removing and Install-
ing the Lamp Unit
Info
• Be sure to remove the lamp unit by the
handle. Be sure not to touch the glass
surface of the lamp unit or the inside of
the projector.
• To avoid injury to yourself and damage
to the lamp, be sure to carefully follow
the steps below.
• Do not loosen other screws except for the
lamp unit cover and lamp unit.
(Only the silver screws are loosened).
• Please refer to the installation manual
included with the lamp unit.
1
Press 
STANDBY
 on the projector
or 
 on the remote control to
put the projector into the
standby mode.
• Wait until the cooling fan stops.
Warning!
• Do not remove the lamp unit from the
projector right after use. The lamp will
be very hot and may cause burn or
injury.
2
Disconnect the power cord.
• Unplug the power cord from the AC
socket.
• Leave the lamp until it has fully cooled
down (about 1 hour).
3
Change the air filter.
• Change the air filter whenever you in-
stall the lamp unit (see pages 
81
 and
82
).
4
Remove the lamp unit cover.
• Loosen the user service screw that
secures the lamp unit cover. Then
open the cover in the direction of the
arrow.
-86
Regarding the Lamp
AC socket
STANDBY button
STANDBY
button
Page of 106