XG-C55X (serv.man13). Trouble shooting table - Sharp Projector Service Manual (repair manual). Page 6

Read Sharp XG-C55X (serv.man13) Service Manual online

39
XG-C55X
TROUBLE SHOOTING TABLE (Continued)
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Checking the RGB signal.
Are the RGB signals outputted from 
pin(16), (18) and (20) of IC3101?
Are their signals outputted from 
pins(26), (28) and (30) of P3102?
Are their signals inputted into 
pins(1), (5) and (25)?
Are their signals inputted into 
pins(54), (58) and (62)?
Are their signals outputted from 
pin(45)-(54), pins(57)-(66) and 
pins(69)-(78) of P8001?
Are their signals inputted into 
IC1101, IC1201, IC1301 and 
IC1401?
Are their signals inputted into 
SC1101, SC1201 and SC1301?
Yes
Check the connection of LCD 
panels
And when video signal and OSD 
are also not displaied, replace the 
LCD panels. 
Check IC3101 and its peripheral 
circuits.
Check SC3102, P3102 and 
their peripheral circuits.
Check Q2419, Q2420 and their 
peripheral circuits.
Check IC2401, Q2401, Q2402 and 
Q2404 and their peripheral circuits.
Go to "Checking the PC I/F unit". 
Check IC1101, IC1201, IC1301 
and IC1401 and their peripheral 
circuits.