Read Sharp XG-C55X (serv.man12) Service Manual online
27
XG-C55X
No.
Adjustment Items
Adjustment Conditions
Adjustment Procedures
17
Adjustment of
COMPO white
balance
COMPO white
balance
1. Feed the DTV monoscope pattern
signal.
2. Select the following group and sub-
jects.
Group: DLP
Subjects: C-R1-BLK, C-B1-BLK
Group: DLP
Subjects: C-R1-BLK, C-B1-BLK
1. Using the set's control switch or the
remote controller button, adjust the
settings to have the same white bal-
ance as on the standard monitor.
settings to have the same white bal-
ance as on the standard monitor.
20
Adjustment of
sRGB white
balance
sRGB white
balance
1. Feed the RGB 50% gray pattern
signal.
2. Select the following group and sub-
jects.
Group: OUTPUT1
Subjects: S-R1-BLK, S-R1-GAIN, S-
G1-BLK, S-G1-GAIN, S-B1-BLK, S-
B1-GAIN
Group: OUTPUT1
Subjects: S-R1-BLK, S-R1-GAIN, S-
G1-BLK, S-G1-GAIN, S-B1-BLK, S-
B1-GAIN
3. Have the BM-5 brightness meter and
the standard white board at hand.
1. Make the S-R1-BLK setting the same
as the R1-BLK one.
Make the S-G1-BLK setting the same
as the R1-BLK one.
Make the S-B1-BLK setting the same
as the R1-BLK one.
Make the S-R1-GAIN setting the
same as the R1-GAIN one.
Make the S-G1-BLK setting the same
as the R1-BLK one.
Make the S-B1-BLK setting the same
as the R1-BLK one.
Make the S-R1-GAIN setting the
same as the R1-GAIN one.
2. Adjust the S-B1-GAIN and S-G1-
GAIN settings so that the chroma-
ticity on the brightness meter should
be as follows.
x: .313±7/1000
y: .350±10/1000
ticity on the brightness meter should
be as follows.
x: .313±7/1000
y: .350±10/1000
18
Automatic color
irregularity correc-
tion
irregularity correc-
tion
1. Apply the automatic color correc-
tion using the automatic color irregu-
larity correction system (ccdc).
larity correction system (ccdc).
1. Make sure that no remarkable uneven
color remains on the screen.
19
Checking of
tracking
tracking
1. Input the RGB 10-step gray-scale
(inverse vertically) signal.
2. Select the following group and sub-
ject.
Group: LINE
Subject: OPT-MECH
Group: LINE
Subject: OPT-MECH
Check the tracking of the gradation on
the lower side.
In case that it is bad, adjust the OPT-
MECH value to the optimum.
(It takes 2 - 3 seconds for changing for
selection.)
0:Red and blue up
1:Red and blue down
2:Initial value (Normal)
the lower side.
In case that it is bad, adjust the OPT-
MECH value to the optimum.
(It takes 2 - 3 seconds for changing for
selection.)
0:Red and blue up
1:Red and blue down
2:Initial value (Normal)
Cautions on 3D irregular color correction adjustment
The following measurement and adjustment must be carried out:
• In a dark room (take care for stray light)
• Using diffuse reflection type (mat type) screen in the uniform conditions.
The following measurement and adjustment must be carried out:
• In a dark room (take care for stray light)
• Using diffuse reflection type (mat type) screen in the uniform conditions.
Settings of the projector must be carried out in the following conditions:
• Do not save power (to keep the lamp to the stable condition during measurement)
• Automatic search cancel (to fix INPUT1)
• INPUT1 RGB mode (cancel the component mode of INPUT 1, just in case)
• Do not save power (to keep the lamp to the stable condition during measurement)
• Automatic search cancel (to fix INPUT1)
• INPUT1 RGB mode (cancel the component mode of INPUT 1, just in case)
(1) System setting (“setting” - “system setting”)
System optional
Simultaneous write in of 3D correction value:
No (not checked)
Char transmission interval:
0 ms
Binary interval:
2 ms