XG-C435X/C465X
2 – 1
XG-C435X
Service Manual
 
CHAPTER 2. 
THE OPTICAL UNIT OUTLINE
[1] THE OPTICAL UNIT OUTLINE
1. Layout for proper setup of the optical components and parts (top view)
Output polarizer R
Output Pre-polarizer R
LCD (R)
Input polarizer R
Dichroic filter R
Condenser lens R
Projection Lens
Cross dichroic
prism
M3
R
reflector
CL4
CL5
Condenser lens 5
Input polarizer G
Input Pre-polarizer G
Condenser lens G
M3
M2
CL4
R
ref
le
ctor
Condenser lens 4
M1
LCD (G)
CL3-G
B
re
fle
ctor
G
re
flec
tor
CL3
CL1
CL2
PBS
Condenser lens 2
Condenser lens 1
Light source
(Lamp)
Input polarizer B
Output pre pre-polarizer B
Output pre-polarizer G
Output pre-pre-polarizer G
Output pre-polarizer B
Output polarizer B
Output polarizer G
Input pre-polarizer B
LCD (B)
Condenser lens B
FLYEYE LENS (OUTPUT)
FLYEYE LENS (INPUT)
B
re
flec
tor
M4
XG-C435X/C465X
2 – 2
2. Adjusting the mirrors
This adjustment is needed when any of the optical parts of the optical mechanism has been replaced.
1. Disconnect the flat cables from all the LCD panels.
2. Light up the lamp.
3. Project a white-light image and check to see if there is any color tint in any direction. If any, use the M2, M4 and M5
adjusting levers.
4. Loosen the adjusting lever lock screws, make adjustments, and tighten up the lock screws.
XG-C435X/C465X
2 – 3
3. Replacing the prism holder unit
1. Remove the 2 lock screws, and take the prism holder unit out of the optical unit.
2. Replace the prism holder unit with new one. Take the above step 1 in reverse order.
NOTE: Even if just one of the LCD panels is defective, it is necessary to replace the entire prism unit. Do not replace
just the defective LCD panel only. Under the present circumstances, please do not touch the display part of
LCD.
G-LCD panel
Optical unit
B-LCD panel
Prism holder unit lock screws
R-LCD panel
XG-C435X/C465X
2 – 4
4. How to replace LCD panel 
• As high precision is required for assembling the prism folder unit, it should be done only in the case where any appropriate, exclusive equipment
Stage (
≤ 5µm adjustment precision)) is available. If no such equipment is available, it is requested to replace
the prism folder unit .
• The three LCD panels in the prism folder unit are combined by adjusting the difference in their characteristics when producing at the factory. If any
of the panels is replaced, more or less discoloration may occur while a dark screen is projected (see the Fig. below).
1. Remove three screws.
2. Replace the LCD.
3. Tighten the screw with 0.15±0.03N
•m.
4. Dissolve the UV adhesive once, and bond the LCD panel again after matching its position.
Partial discoloration appearing
at diagonal corner sections
Three positions -
fixing the panel with screw
Page of 4
Display

Download Sharp XG-C465X (serv.man3) Service Manual (Repair Manual)

Here you can read online and download Sharp XG-C465X (serv.man3) Service Manual in PDF. XG-C465X (serv.man3) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp XG-C465X (serv.man3) Projector. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.