XG-C40XE (serv.man4). Service Manual - Part 1 - Text (1-31) - Sharp Projector Service Manual (repair manual). Page 26

Read Sharp XG-C40XE (serv.man4) Service Manual online

26
XG-C40XU/XE
2.0V DC
6.2
±
0.2V DC
PSIG
GND
(Adjust with PSIG-H.)
(Adjust with PSIG-L.)
No.
Adjusting point
Adjusting conditions
Adjusting procedure
8
P SIGNAL
1. Connect the oscilloscope to
TP1701 for red.
    TP1702 for green
    TP1703 for blue.
2. Make the following choice:
Group : OUTPUT 2
Subject : PSIG-H
: PSIG-L
»
Adjust the PSIG waveform to the one shown below.
»
For the green and blue colours, make sure their wave-
forms are similar to that of the red colour.
»
Make sure the pin stripe of every 12 dot doesn't ap-
pear at 10 steps signal of side nays.
(Appearing white pin stripe or black one, adjust the
PSIG-H.)
9
Panel ghost
adjustment
1. Project the XGA60Hz ghost
test pattern (black charac-
ters in bold on the halftone
RGB background).
Group: OUTPUT3
2. GCK-PHASE adjustment
Make sure the setting is fixed
at 8 (initial value).
3. EN-WIDTH adjustment
Make sure the setting is fixed
at 8 (initial value).
4. ENR-PHASE adjustment (R-
LCD ghost adjustment)
5. ENG-PHASE adjustment
(G-LCD ghost adjustment)
6. ENB-PHASE adjustment (B-
LCD ghost adjustment)
»
ENR-PHASE adjustment (R-LCD ghost adjustment)
1
Increase the setting until a ghost image (see
Note) becomes visible at the left of the back
characters on the R half-tone background.
2
Lower the setting point by point until the left-
hand ghost image (
1
 above) disappears.
3
Further lower the setting by one point.
»
ENG-PHASE adjustment (G-LCD ghost adjust-
ment)
Adjust the G ghost image by following the same
procedures described under step 1 above.
»
ENB-PHASE adjustment (B-LCD ghost adjust-
ment)
Adjust the B ghost image by following the same
procedures described under step 1 above.
Note: Left-hand ghost image: Characters are shown
double 12 dots left from the real characters.
Reference: This adjustment is made because the
EPSON LCD panel may have 1- or 2-
point differences due to lot-by-lot varia-
tions.
10
Sample-and-
hold pulse
phase
RCK-PHASE
GCK-PHASE
BCK-PHASE
1. Feed the XGA mode 75-Hz
black signal.
2. Make the following choice:
Group : OUTPUT 3
Subject : SH-PHASE
(Have the standard level at
2.)
Fix the RCK-, GCK- and
BCK-PHASE settings all to
8.
»
Using the control switches or the remote controller
buttons, make sure that the “OUTPUT 3” charac-
ters are not blurry and there is no ghost image. If
such blur or ghost occurs, finely adjust the setting
in the range of 7~9.
Page of 31
Display

Click on the first or last page to see other XG-C40XE (serv.man4) service manuals if exist.