XG-C40XE (serv.man19). Part 3 - Sharp Projector User Guide / Operation Manual. Page 13

Read Sharp XG-C40XE (serv.man19) User Guide / Operation Manual online

Maintenance &
Tr
oubleshooting
50
Replacing the Projection Lamp
CAUTION:
• Potential hazard of glass particles if lamp ruptures. Please have Sharp Authorised LCD Projector
Dealer or Service Centre replace lamp if rupture occurs.
• Do not remove the lamp cage directly after operation of the projector. The lamp may be extremely
hot. Wait at least one hour after the power cord is disconnected to allow the surface of the lamp cage
to fully cool before removing the lamp cage.
It is recommended that the lamp be replaced after approximately 1,900 cumulative hours of use or when you
notice a significant deterioration of the picture and colour quality. Carefully change the lamp by following the steps
below.
If the new lamp does not light after replacement, take your projector to the nearest Sharp Authorised LCD Projector
Dealer or Service Centre for repair. Purchase a replacement lamp unit (lamp/cage module) of the current type
BQC-XGC40XU/1 from your nearest Sharp Authorised LCD Projector Dealer or Service Centre. Then carefully
change the lamp by following the instructions below. If you wish, you may have the lamp replaced at your nearest
Sharp Authorised LCD Projector Dealer or Service Centre.
Removing and installing the lamp unit
CAUTION
Tab
4
6
5
Replace the new air
filter.
1
3
Turn off the power.
2
Disconnect the power
cord.
Unplug the power cord from the
AC socket.
Remove the bottom
filter cover.
Replace the filter cover.
Insert the tab on the end of the
filter cover into the filter cover
opening and press the filter
cover into position.
Press POWER OFF. Wait until
the cooling fan stops.
Place the new air filter
underneath the tabs on the filter
frame.
or
Turn over the projector. Press the
tab and lift open the filter cover
in the direction of the arrow.
Tab
Grasp the air filter between your
fingers and lift it out of the filter
cover.
Remove the air filter.
• Be sure to remove the lamp cage by the handle. Be sure not to touch the glass surface of the lamp cage or the inside of
the projector.
• To avoid injury to yourself and damage to the lamp, be sure to carefully follow the steps below.
• Be sure to change the air filter during lamp replacement. The air filter comes packaged with the lamp unit.
XG-C40XE/CD (E)-f
01.8.1, 5:59 PM
50
Page of 25