PG-M20X (serv.man27). Appendix - Sharp Projector User Guide / Operation Manual. Page 6

Read Sharp PG-M20X (serv.man27) User Guide / Operation Manual online

POWER button
Regarding the Lamp (cont.)
Removing and Install-
ing the Lamp Unit
Info
• Be sure to remove the lamp unit by the
handle. Be sure not to touch the glass
surface of the lamp unit or the inside of
the projector.
• To avoid injury to yourself and damage
to the lamp, be sure to carefully follow
the steps below.
• Do not remove other screws except for
the lamp cover screws.
• Please refer to the installation manual
included with the lamp unit.
1
Press 
 on the projector to
turn off the power.
• Wait until the cooling fan stops.
2
Disconnect the power cord.
• Unplug the power cord from the AC
socket.
• Leave the lamp until it has fully cooled
down (about 1 hour).
3
Remove the lamp unit cover.
• Turn over the projector, and loosen the
user service screw that secures the
lamp unit cover. Then slide the cover
in the direction of the arrow.
Lamp
unit
BQC-PGM20X//1
AC socket
User service screw
-72