PG-M20S (serv.man11). Troubleshooting tables - Sharp Projector Service Manual (repair manual). Page 19

Read Sharp PG-M20S (serv.man11) Service Manual online

46
PG-M20S
PG-M20X
Feed the composite video signal to 
INPUT 3.
Select INPUT 3 using the set's key 
or the remote controller.
Is there any disturbance in the 
picture?
The video input is normal. End.
Is the color normal?
Is the picture appear?
Go to "Checking of Video 
Sync Signal".
No
Yes
Input PWB is defective.
Q8002 and its periphery are 
defective.
IC8015 is defective.
No
Is there the specified signal 
at R8114?
No
5
5
No
Checking of Video Input
Go to "Checking of Video 
Sync Signal".
Carry out the process 
adjustment.
Yes
No
Yes
Check the clock signal of IC8015 
by FL8114.
Is the clock signal normal?
Yes
IC8025 and its periphery are 
defective.
Yes
Yes
Is the video signal inputted to 
C8141?
No
Go to "Checking of Video Sync 
Signal".
» 
PC I/F Unit-10/12
Page of 21
Display