Read Sharp PG-M15 (serv.man12) Technical Bulletin online
LV078
Sharp Electronics (UK) Ltd., Technical Services Group
Model
PG-M15X, PG-M15S
Problem
Lamp does not light up
Cause
Ballast unit failure
Servicing
If you received a service call from customer with this failure, please replace the defective
ballast unit with the improved one (9HJ7583101003).
ballast unit with the improved one (9HJ7583101003).
The improved ballast unit (9HJ7583101003) does not have the fuse cover (ref no. 5-2:
9HJ5183142002). When you replace the old ballast unit with the improved one, be sure to
attach the fuse cover to the improved ballast unit. You can remove the fuse cover from old
ballast unit and use it to the improved ballast unit.
9HJ5183142002). When you replace the old ballast unit with the improved one, be sure to
attach the fuse cover to the improved ballast unit. You can remove the fuse cover from old
ballast unit and use it to the improved ballast unit.
Ref. no.
Part code
Description
Price
---
9HJ7583101003
Ballast unit
DA
LAMP DOES NOT LIGHT UP (BALLAST UNIT FAILURE)
TECHNICAL BULLETIN
Date:
22 May 2003
Model: PGM15X/S