PG-M10SE (serv.man6). Disassembly and reassembly - Sharp Projector Service Manual (repair manual). Page 3

Read Sharp PG-M10SE (serv.man6) Service Manual online

12
PG-M10SU/SE
PG-M10XU/XE
7) Lamp driver  (See Fig. 7.)
Remove the two screws (S-16 and S-17 each)
shown in Fig. 7, and dismount the lamp driver.
Lamp Driver
S-19
S-16
S-17
Fig. 7
 8) Lens base  (See Fig. 8.)
Remove the four screws (S-7) shown in Fig. 8, and
detach the lens base.
Note: When disassembling or reassembling, be careful
not to get the wires caught.  Do not dismount
the spherical mirror and the cylinder mirror out
of the lens base.  Otherwise the adjustment will
be lost to produce shadows at the corners of
the screen.
Fig. 8
Lens Base
S-7
S-7
S-7
9) Heat sink  (See Fig. 9.)
Remove the two screws (S-11) shown in Fig. 9, and
detach the heat sink.
Note: Be  careful to fit the heat sink in the correct
direction.
Heat Sink A
Heat Sink B
S-11
Fig. 9
10)DMD and F/M PWB  (See Fig. 10.)
Remove the four screws (S-9) shown in Fig. 10,
and detach the DMD and F/M PWB from the lens
base.
Note: Take care not to touch the elastomer, DMD
surface or terminals, and F/M PWB terminals
by finger. When reassembling, be careful not to
allow dust or dirt on the parts.  Special care
should be taken in handling the DMD, elastomer
and F/M PWB, which will directly affect the image
quality.
Elastomer
Elastomer
Holder
DMD
F/M PWB
F/M Angle
S-9
Fig. 10
Page of 5