PG-M10SE (serv.man23). Countermeasure when power indicator does not light up - Sharp Projector Technical Bulletin (repair manual). Page 2

Read Sharp PG-M10SE (serv.man23) Technical Bulletin online

LV057
Sharp Electronics (UK) Ltd., Technical Services Group
Parts replacement procedure on the DC Power Supply Unit
1) Parts needed
This parts kit contains the following parts.
2) Procedure
1) Replace Q106 with new one (9FU91130Q106).
2) Replace Q107 with new one (9FU91130Q106).
3) Replace R129 with new one (9FU91130R129).
4) Replace F101 with new one (9FU91130F101).
5) Replace Lamp Cover Ass’y (#75) with new type (9FU770820711).
3) Pictures of each parts.
Q106, Q107
Page of 3
Display