1
PG-M10SU/SE
PG-M10XU/XE
SHARP CORPORATION
DLP PROJECTOR
DLP PROJEKTOR
In the interests of user-safety (Required by safety regulations in some countries) the set should be restored
to its original condition and only parts identical to those specified should be used.
Im lnteresse der Benutzersicherheit (erforderliche Sicherheitsregeln in einigen Ländern) muß das Gerät in seinen
Originalzustand  gebracht werden.  Außerdem dürfen für die spezifizierten Bauteile nur identische Teile verwendet
werden.
MODELS
MODELLE
CONTENTS / INHALT
• SPECIFICATIONS .............................................. 2
• NOTE TO SERVICE PERSONNEL .................... 3
• OPERATION MANUAL ...................................... 4
• DISASSEMBLY AND REASSEMBLY ............... 10
• REPLACING THE LAMP .................................. 15
• BLOCK DIAGRAM OF OPTICAL SYSTEM
PRINCIPLE ...................................................... 16
• OPTICAL ADJUSTMENT AND MEASURING .. 17
• SAFETY DEVICE ............................................. 20
• TROUBLE SHOOTING TABLE ........................ 21
• BLOCK DIAGRAM ........................................... 43
• PARTS LIST ..................................................... 44
• PACKING OF THE SET ................................... 51
Page
• TECHNISCHE DATEN ..................................... 22
• HINWEISE FÜR DAS
WARTUNGSPERSONAL ................................. 23
• BEDIENUNGSANLEITUNG ............................. 24
• ZERLEGUNG UND ZUSAMMENBAU ............. 30
• AUSWECHSELN DER LAMPE ........................ 35
• BLOCKDIAGRAMM FÜR OPTISHES
SYSTEMPRINZIP ............................................ 36
• OPTISCHE EINSTELLUNGEN UND
MESSUNG ....................................................... 37
• SICHERHEITSEINRICHTUNG ........................ 40
• FEHLERSUCHTABELLE ................................. 41
• BLOCKSCHALTBILD ....................................... 43
• ERSATZTEILLISTE .......................................... 44
• VERPACKEN DES GERÄTS ........................... 51
Seite
S90i7PG-M10SU
SERVICE MANUAL
SERVICE-ANLEITUNG
PG-M10SU/SE
PG-M10XU/XE
2
PG-M10SU/SE
PG-M10XU/XE
Specifications
3
PG-M10SU/SE
PG-M10XU/XE
NOTE TO SERVICE
PERSONNEL
 UV-RADIATION PRECAUTION
The light source,  metal halide lamp,  in the DLP
projector emits small amounts of UV-Radiation.
AVOID DIRECT EYE AND SKIN EXPOSURE.
To ensure safety please adhere to the following:
1. Be sure to wear sun-glasses when servicing the
projector with the lamp
turned “on” and the top
enclosure removed.
2. Do not operate the lamp outside of the lamp housing.
3. Do not operate for more than 2 hours with the
enclosure removed.
UV-Radiation and Medium Pressure
Lamp Precautions
1. Be sure to disconnect the AC plug when replacing
the lamp.
2. Allow one hour for the unit to cool down before
servicing.
3. Replace only with same type lamp. Type BQC-
PGM10X//-1 rated 85V/130W.
4. The lamp emits small amounts of UV-Radiation,  avoid
direct-eye contact.
5. The medium pressure lamp involves a risk of
explosion. Be sure to follow installation instructions
described below and handle the lamp with care.
12345678901234567890123456789012123456789012345
12345678901234567890123456789012123456789012345
12345678901234567890123456789012123456789012345
12345678901234567890123456789012123456789012345
12345678901234567890123456789012123456789012345
12345678901234567890123456789012123456789012345
12345678901234567890123456789012123456789012345
1234567890123456789012345678901212345678901234
1234567890123456789012345678901212345678901234
1
2
DANGER !  –– Never turn the power on without the
lamp to avoid electric-shock or damage of the
devices since the stabilizer generates high voltages
at its start.
UV-RADIATION PRECAUTION (Continued)
Lamp Replacement
Note:
Since the lamp reaches a very high temperature
during units operation replacement of the lamp
should be done at least one hour after the power
has been turned off.  (to allow the lamp to cool off.)
Installing the new lamp, make sure not to touch the
lamp (bulb) replace the lamp by holding its reflector
2
.
[Use original replacement only.]
Since small amounts of UV-Radiation are emitted
from an opening between the duct cover and the
lamp housing, it is recommended to place the LENS
CAP on the opening during servicing to avoid eye
and skin exposure (Fig. 1).
Notes:
»
Please obtain a lens cap before servicing a model
PG-M10SU/SE, PG-M10XU/XE that is received
without one.
»
The color wheel is running at high speed. Do not
touch it nor bring anything nearby.
Lamp
Reflector
COLOR WHEEL                              LENS CAP
Figure 1.
4
PG-M10SU/SE
PG-M10XU/XE
Location of Controls
Page of 30
Display

Download Sharp PG-M10SE (serv.man11) Service Manual (Repair Manual)

Here you can read online and download Sharp PG-M10SE (serv.man11) Service Manual in PDF. PG-M10SE (serv.man11) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp PG-M10SE (serv.man11) Projector. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.