Read Sharp PG-F312X (serv.man2) Service Manual online
XR-32S/XR-32X/PG-F212X/PG-F312X
2 – 5
[3] Removing the Optical Mechanism Unit and Fan Unit
1. Remove the Fan unit.
2. Remove the 2 lock screws
, and detach the socket.
3. Remove the 4 lock screws
and 1 lock screw
and detach the Optical Mechanism Unit.
6
6
Fan Unit
7
8
OPTICAL MECHANISM Unit
7
7
7
OPTICAL MECHANISM Unit
8
Click on the first or last page to see other PG-F312X (serv.man2) service manuals if exist.