Electrical Adjustments
Version 1.5
Issue 04/2006
41
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
No.
Adjustment Items
Adjustment Conditions
Adjustment Procedures
17
Adjustment of COMPO
white balance
1. Feed the DTV monoscope pattern
signal.
2. Select the following group and
subjects.
Group: DLP
Subjects: C-R1-BLK, C-B1-BLK
1. Using the set's control switch or the
remote controller button, adjust the settings
to have the same white balance as on the
standard monitor.
18
Adjustment of sRGB white
balance
1. Feed the RGB 50% grey pattern
signal.
2. Select the following group and
subjects.
Group: OUTPUT1
Subjects: S-R1-BLK, S-R1-GAIN,
SG1-
BLK, S-G1-GAIN, S-B1-BLK, SB1-
GAIN
3. Have the BM-5 brightness meter
and the standard white board at hand.
1. Make the S-R1-BLK setting the same as
the R1-BLK one.
Make the S-G1-BLK setting the same as the
R1-BLK one.
Make the S-B1-BLK setting the same as the
R1-BLK one.
Make the S-R1-GAIN setting the same as
the R1-GAIN one.
2. Adjust the S-B1-GAIN and S-G1-
GAIN settings so that the chromaticity on the
brightness meter should be as follows.
x: .313±7/1000
y: .350±10/1000
Teaching intervals:
18
Brightness adjustable direction:
Brightness up by increasing the setting (to be
checked)
Adjusting points:
Three dimension (to be checked)
Gradation 4 (to be checked)
Gradation 5 (to be checked)
Gradation 6 (to be checked)
Other gradations not to be checked
Adjustable colours:
R, G and B adjustable (to be checked)
(2) Colour irregularity correction (adjustment)
C50 conditions set-up (
)
Correction procedure settings
Gradation 7: 
2. Lower-gradation correction value to be used.
Gradation 6:
0. Correction with correction coefficient.
Gradation 5: 
0. Correction with correction coefficient.
Gradation 4: 
0. Correction with correction coefficient.
Gradation 3: 
1. Upper-gradation correction value to be used.
Gradation 2: 
1. Upper-gradation correction value to be used.
Gradation 1: 
4. Initial value to be used.
Gradation 0: 
4. Initial value to be used.
For the model in question, select the name entered in (2) to start the colour irregularity
correction. If the set has its optical characteristics rather different from the standard ones or if
the set has some colour irregularity lines missing, do the teaching for that set in particular.
Use its specified correction coefficients in making the adjustment.
No.
Adjustment Items
Adjustment Conditions
Adjustment Procedures
19
Checking and
readjustment of
white balance
1. The adjusting conditions for each
item are as follows:
For RGB input, see Item 7.
For video input, see Item 13.
For COMPO input, see Item 16.
1. Make sure the white balance is as
specified on the standard monitor.
For readjustment, proceed in the order
of RGB input, video input and
COMPO input.