Read Sharp PG-C45X (serv.man31) User Guide / Operation Manual online
Appendix
-81
Replacing the Air Filter
Air filter
Tab
M4
M4
M4
M4
• This projector is equipped with air fil-
ters to ensure the optimal operating
condition of the projector.
condition of the projector.
• The air filters should be cleaned ev-
ery 100 hours of use. Clean the filters
more often when the projector is used
in a dusty or smoky location.
more often when the projector is used
in a dusty or smoky location.
• Ask your nearest Sharp Authorized
Projector Dealer or Service Center to
exchange the filter (PFILDA005WJZZ)
when it is no longer possible to clean.
exchange the filter (PFILDA005WJZZ)
when it is no longer possible to clean.
Cleaning and replacing
the bottom air filter
the bottom air filter
1
Turn off the power and discon-
nect the power cord.
nect the power cord.
• Press
. Wait until the cooling fan
stops.
2
Remove the bottom filter cover.
• Turn over the projector. Grab the tab
and slide open the filter cover in the
direction of the arrow.
direction of the arrow.
3
Remove the air filter.
• Pick the air filter up with your fingers
and lift it out of the filter cover.
Power (OFF) button
Power
(OFF)
button
(OFF)
button
Air filter
(not removable)
PG-C45X#E_PDF#p79_93.p65
03.2.17, 11:39 AM
81
Click on the first or last page to see other PG-C45X (serv.man31) service manuals if exist.