PG-C45X (serv.man11). Troubleshooting table - Sharp Projector Service Manual (repair manual). Page 14

Read Sharp PG-C45X (serv.man11) Service Manual online

42
PG-C45X
TROUBLE SHOOTING TABLE for PC I/F UNIT (Continued)
No
No
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
No
Checking of GA4 and Its Periphery
Select R, G and B individually on 
the pattern menu in the process 
mode.
Is picture outputted appropriately 
in R, G and B?
Checking of GA4 and its periphery 
ends.
Measure the signals at pins (54), 
(66) and (78) of SC8001 on the 
oscilloscope. These signals are 
MSB of B/G/R/.
Do the oscilloscope-measured 
signals match with those selected 
on the pattern menu?
The OUTPUT PWB is defective.
Does the clock signal come to pins 
(40) and (42) of SC8001?
Is there the clock (37.5 MHz) 
signal at TL8114?
IC8029 is defective.
Is there the clock (37.5 MHz) 
signal at FL8110?
X8005 is defective.
IC8025 is defective.
Measure the signals at TL8106, 
TL8107, TL8108, TL8110 and 
TL8111 on the oscilloscope.
Do the oscilloscope-measured 
signals match with those selected 
on the pattern menu?
IC8025 is defective.
IC8029 is defective.