Read Sharp PG-C45X (serv.man10) Service Manual online
21
PG-C45X
4
Checking of
sample-and-hold
pulse phase
sample-and-hold
pulse phase
1. Feed the XGA-mode 75-Hz black
signal.
2. Select the following group and sub-
ject.
Group: OUTPUT3
Subject: GCK-PHASE
Group: OUTPUT3
Subject: GCK-PHASE
No.
Adjustment Items
Adjustment Conditions
Adjustment Procedures
1. Check the fixed value.
Fixed value: 6
5
Adjustment of
RGB counter-
voltage
RGB counter-
voltage
1. Feed the counter-voltage adjust-
ment signal (XGA) prepared by the
Technical Department.
Technical Department.
2. Select the following group and sub-
jects.
Group: OUTPUT3
Subject: RC (R), GC (G), BC (B)
Group: OUTPUT3
Subject: RC (R), GC (G), BC (B)
1. Using the set's control switch or the
remote controller button, adjust the
settings to minimize flickers.
settings to minimize flickers.
2. If the results are inconsistent at the
center and on both sides onscreen,
readjust the settings to get the same
results on both sides.
readjust the settings to get the same
results on both sides.
6
Adjustment of
RGB gradation
reproduction
RGB gradation
reproduction
1. Feed the SMPTE pattern signal.
2. Select the following group and sub-
2. Select the following group and sub-
ject.
Group: OUTPUT1
Subject: G1-BLK
Group: OUTPUT1
Subject: G1-BLK
1. Confirm that the 100% and 95% white
gradation as well as the 0% and 5%
black gradation are discernible.
black gradation are discernible.
2. If the white gradation looks differently,
finely adjust the G1-BLK setting.
7
Adjustment of
RGB white bal-
ance
RGB white bal-
ance
1. Feed the 32-step gray scale signal
(XGA, 60 Hz).
2. Select the following group and sub-
jects.
Group: OUTPUT1
Subjects: R1-BLK (R), B1-BLK (B)
Group: OUTPUT1
Subjects: R1-BLK (R), B1-BLK (B)
1. Adjust the R1-BLK and B1-BLK set-
tings to have the specified gradation
balance (according to the standard
monitor).
balance (according to the standard
monitor).
8
Adjustment of
video AGC
video AGC
1. Feed the NTSC 10-step gray scale
signal.
2. Select the following group and sub-
ject.
Group: VIDEO
Subject: AGC-ADJ
Group: VIDEO
Subject: AGC-ADJ
3. Connect the oscilloscope between
TP4501 and TP4502
1. Using the set's control switch or the
remote controller button, adjust the
setting so that the white-to-black level
is 0.72 Vp-p±0.01 V.
setting so that the white-to-black level
is 0.72 Vp-p±0.01 V.
9
Adjustment of
video brightness/
contrast
video brightness/
contrast
1. Feed the NTSC100% window pat-
tern signal.
2. Select the following group and sub-
jects.
Group: VIDEO
Subject: AUTO, PICTURE/BRIGHT
Group: VIDEO
Subject: AUTO, PICTURE/BRIGHT
1. Feed the signal. Using the set's con-
trol switch or the remote controller
button, select the subject AUTO. The
setting will adjust itself.
button, select the subject AUTO. The
setting will adjust itself.
2. Then adjust the PICTURE/BRIGHT
setting until the signal becomes bit-
less.
less.
Click on the first or last page to see other PG-C45X (serv.man10) service manuals if exist.