PG-C30XE (serv.man4). Contents, Removing of major parts, Resetting the total lamp timer, The optical unit outline, Covergence and focus adjustment, Electrical adjustment, Adjusting hte PC interface, and Troubleshooting table - Page 1-43 - Sharp Projector Service Manual (repair manual). Page 41

Read Sharp PG-C30XE (serv.man4) Service Manual online

41
PG-C30XE
C
Yes
Yes
No
No
C
Yes
Yes
No
No
Yes
Yes
Yes
Yes
No
No
Is there signal at TL613?
No
Are there signals at pins (10) thru (20) 
of IC8051?
CON4 (P8405), IC8051 or its 
peripheral parts faulty.
No
IC8609 or its perpheral parts faulty.
output PWB faulty.
No
IC8029 or its peripheral circuit faulty.
Checking the S-
XGA's green video 
circuit and its 
peripheral circuits
Checking the VGA's 
green video circuit 
and its peripheral 
circuits
Yes
No
Is there signal at pin (23) of CON2 
(P8404) connector?
Check the video 
system's green 
video circuit and its 
peripheral circuits
Is there signal at pin (124) of IC8606?
Is there signal at pin (124) of IC8606?
output PWB faulty.
Are there signals at pins (68) thru 
(75), (78), (81) thru (85), (87) and (88) 
of IC8606?
IC8606 or its peripheral circuit faulty.
Are there signals at TL8045 and 
TL8047?
Are there signals at pins (165) thru 
(177) of IC8020?
IC8025 or its peripheral circuit faulty.
Are there signals at pins (178) thru 
(187) of IC8020?
IC8020 or its peripheral circuit faulty.
Are there signals at pins (68) thru 
(75), (78), (81) thru (85), (87) and (88) 
of IC8606?
Yes
TROUBLE SHOOTING TABLE FOR PC I/F UNIT-4