PG-C20XE (serv.man6). Section 3 - Troubleshooting - Sharp Projector Service Manual (repair manual). Page 7

Read Sharp PG-C20XE (serv.man6) Service Manual online

37
PG-C20XU
PG-C20XE
AN-Z7T
YES
YES
Checking the input signal 
setting
Is the input signal setting 
as specified?
Select the specified signal.
Is the connector properly 
connected?
NO
Reconnect the connector.
End
NO
1
2
YES
YES
YES
YES
Checking the sync signal
Is there vertical sync signal 
at TP8003?
Is there horizontal sync 
signal at pin (3) of IC3008 
connection terminal PWB?
IC3008 or its peripheral 
circuit defective. Or 
SC3003 in poor contact.
Is there horizontal sync 
signal at pin (3) of IC3006 
connection terminal PWB?
IC3006, IC3010 or their 
peripheral circuit defective. 
Or SC3003 in poor 
contact.
Is there horizontal sync 
signal at TP8002?
NO
End
SC3001 or its peripheral 
circuit defective.
NO
NO
NO
Page of 12