Read Sharp PG-A10XA (serv.man2) Service Manual online
32
PG-A10X-A
YES
YES
YES
YES
NO
Checking the power unit
Are the connectors CN701,
CN702 and CN751
inserted completely?
CN702 and CN751
inserted completely?
Insert the connectors
CN701, CN702 and
CN751 tightly?
CN701, CN702 and
CN751 tightly?
Replace the bimetal
NO
Replace F701.
NO
Check Q702 for damage.
Replace as required.
Replace as required.
NO
Is the bimetal switch off?
Is there AC voltage (110-
240V) applied across
C701?
240V) applied across
C701?
Disconnect the CN751
connector. Is there 6V
output at pins (3) and (4)?
connector. Is there 6V
output at pins (3) and (4)?
Check the MAIN PWB for
short-circuit.
short-circuit.