5
Remove the lamp unit.
• Loosen the securing screws from the
lamp unit. Hold the lamp unit by the
handle and pull it in the direction of the
arrow. At this time, keep the lamp unit
horizontal and do not tilt it.
6
Insert the new lamp unit.
• Press the lamp unit firmly into the lamp
unit compartment. Fasten the securing
screws.
7
Replace the filter/lamp unit
cover.
• Align the tab on the filter/lamp unit cover
(1) and place it while pressing the tab
(2) to close it. Then tighten the user
service screw (3) to secure the filter/
lamp unit cover.
Info
• If the lamp unit and filter/lamp unit cover
are not correctly installed, the power will
not turn on, even if the power cord is con-
nected to the projector.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
1
Connect the power cord.
• Plug the power cord into the AC socket
of the projector.
2
Reset the lamp timer.
• While simultaneously holding down
 and 
 on the projector, press
 and 
 on the projector.
• “LAMP 0000H” is displayed, indicating
that the lamp timer is reset.
Info
• Make sure to reset the lamp timer only
when replacing the lamp. If you reset the
lamp timer and continue to use the same
lamp, this may cause the lamp to become
damaged or explode.