Read Sharp PG-A10X (serv.man32) User Guide / Operation Manual online
-44
You can use the “Options” menu to enhance the usage for the projector. For operation of the
menu screen, see pages
menu screen, see pages
32
to
35
.
Example: “Options” menu screen for
INPUT 2 (S-Video) mode
Lamp Timer (Life)
(Check-
ing the Lamp Life Status)
You can confirm the cumulative lamp usage time
and the remaining lamp life (percentage).
and the remaining lamp life (percentage).
Display the “Options” menu to check the
lamp life status.
lamp life status.
Description of Lamp Life
Note
• It is recommended that the lamp be changed
when the remaining lamp life becomes 5%.
For lamp replacement, contact your nearest
Sharp Authorized Projector Dealer or Service
Center.
For lamp replacement, contact your nearest
Sharp Authorized Projector Dealer or Service
Center.
• The table above indicates rough estimates in the
case of using only in each mode shown. Remain-
ing lamp life changes within the range of the val-
ues shown depending on the frequency at which
“Eco Mode” is switched to “
ing lamp life changes within the range of the val-
ues shown depending on the frequency at which
“Eco Mode” is switched to “
” (Eco mode) and
“
” (Standard mode) (see page
45
).
Using the “Options” Menu
OSD Display
(Setting On-
screen Display)
This function allows you to turn the on-screen mes-
sages on or off.
sages on or off.
Select “
” (ON) or “
” (OFF) in “OSD
Display” on the “Options” menu.
Description of “OSD Display” Settings
Selectable settings
ON
OFF
OFF
Description
All On-screen Displays are displayed.
INPUT/VOLUME/AV MUTE/FREEZE/
AUTO SYNC/ENLARGE/ “An invalid
button has been pressed.” / “All buttons on
Projector are locked.” are not displayed.
INPUT/VOLUME/AV MUTE/FREEZE/
AUTO SYNC/ENLARGE/ “An invalid
button has been pressed.” / “All buttons on
Projector are locked.” are not displayed.
Remaining lamp life
100%
5%
about
4,500 hours
225 hours
about
3,000 hours
150 hours
Lamp usage condition
Used with only “
”
(Eco mode) in “Eco
Mode”
Used with only “
Mode”
Used with only “
”
(Standard mode) in
“Eco Mode”
“Eco Mode”
Click on the first or last page to see other PG-A10X (serv.man32) service manuals if exist.