PG-A10X (serv.man11). Trouble shooting table - Sharp Projector Service Manual (repair manual). Page 4

Read Sharp PG-A10X (serv.man11) Service Manual online

34
PG-A10X
PG-A10X-SL
AN-A10T
YES
YES
YES
YES
Checking the lamp 
light-up
Reconnect the CN751 
and CN752 harnesses 
tight enough. Or replace 
these harnesses.
Go to "Checking the 
power unit".
Replace the ballast unit.
NO
Go to "Checking the 
microcomputer 
peripherals".
NO
NO
Are DC350-400V voltages 
applied between the pins 
of CN703?
NO
Is the lamp socket 
disconnected?
Reconnect the lamp 
socket tightly.
Are the CN751 and 
CN752 harnesses tight in 
position in the power unit 
and ballast unit as well? 
Are these harnesses free 
of damage?
Are there 3V (High level) 
and 1V applied at pins (1) 
and (13), respectively, of 
CN751 in the power unit?
NO
Checking the RGB 
sync
Check IC6001 and its 
peripheral cuicuits.
NO
YES
Are theire signal inputted 
into pins (30),
(31) of IC6004?
Are theire signal inputted 
into pins (2)
of IC5002, IC5015?
Check RGB terminal and 
its peripheral circuits
Page of 7