Read Sharp MX-XB17 Service Manual online
MX-FX13 FAX SOFT SWITCH 4 - 1
[4] FAX SOFT SWITCH
1. Details
• When outside the set range, the default value is automatically set.
• Never change the soft switch setup which are inhibited to use.
*1: The initial values in this column are for USA. For the initial values for the other destinations, refer to "2. Soft switch initial table."
SW
No.
Bit
No.
Item
Switch selection and function
Initial value *
1
Remark
1
1-8
Information by
country
country
Binary input
1
0
1
1
1
0
1
0
0
1
2
1-8
Not used
0
0
0
0
0
0
0
0
0
1
3
1-7
Not used
1
0
0
0
0
0
0
1
0
8
Flash memory check
measurement range
measurement range
256 byte
0
4
1-8
Not used
0
0
0
0
0
0
0
0
0
0
0
5
1-8
Not used
0
0
0
0
0
0
0
0
0
0
Bit No.
Setting value
1 2 3 4 5 6 7 8
1 0 1 1 0 1 0 1 U.S.A.
0 0 1 0 0 0 0 0 Canada
1 0 1 1 0 1 0 0 U.K.
0 0 0 0 0 1 0 0 Germany
0 0 1 1 1 1 0 1 France
0 0 0 0 1 0 0 1 Australia
1 0 0 1 1 1 0 0 Singapore
0 1 1 0 1 1 0 0 Malaysia
0 1 0 1 0 0 0 0 Hong Kong
1 1 1 1 1 1 1 0 Taiwan
1 0 1 0 1 0 0 1 Thailand
1 1 1 1 1 1 0 1 Middle East
0 1 0 1 0 0 1 1 India
1 0 1 0 0 1 0 1 Sweden
0 1 1 1 1 1 1 0 New Zealand
1 0 1 0 0 0 0 0 Spain
1 0 0 0 1 0 1 1 Portugal
0 1 0 1 1 0 0 1 Italy
1 0 1 0 0 1 1 0 Switzerland
Bit No.
Setting value
1 2 3 4 5 6 7 8
0 0 1 1 1 1 0 0 Finland
0 0 1 1 0 0 0 1 Denmark
1 0 0 0 0 0 1 0 Norway
0 1 1 1 1 0 1 1 Netherlands
0 1 1 0 1 0 0 1 Luxembourg
0 0 0 0 1 1 1 1 Belgium
1 1 1 1 1 0 1 1 Other 3
0 0 0 1 0 1 1 0 Brazil
1 0 0 1 1 1 1 1 South Africa
0 0 1 0 1 1 1 0 Czech
1 1 1 1 1 1 0 0 Slovakia
0 1 0 1 0 0 0 1 Hungary
0 1 0 0 0 1 1 0 Greece
1 0 0 0 1 0 1 0 Poland
1 0 1 1 1 0 0 0 Russia
0 0 0 0 1 0 1 0 Austria
0 1 0 1 0 1 0 0 Indonesia
1 0 0 0 1 0 0 1 Philippines
1
All area
0
256 byte