MX-XB17. Service Manual December 2011. - Sharp Copying Equipment Service Manual (repair manual). Page 11

Read Sharp MX-XB17 Service Manual online

MX-FX13  FAX SOFT SWITCH  4 - 1
[4] FAX SOFT SWITCH
1. Details
• When outside the set range, the default value is automatically set.
• Never change the soft switch setup which are inhibited to use.
*1: The initial values in this column are for USA. For the initial values for the other destinations, refer to "2. Soft switch initial table."
SW
No.
Bit 
No.
Item
Switch selection and function
Initial value *
1
Remark
1
1-8
Information by 
country
Binary input
1
0
1
1
0
1
0
1
2
1-8
Not used
0
0
0
0
0
0
0
1
3
1-7
Not used
1
0
0
0
0
1
0
8
Flash memory check 
measurement range
256 byte
0
4
1-8
Not used
0
0
0
0
0
0
0
0
5
1-8
Not used
0
0
0
0
0
0
0
0
Bit No.
Setting value
1 2 3 4 5 6 7 8
1 0 1 1 0 1 0 1 U.S.A.
0 0 1 0 0 0 0 0 Canada
1 0 1 1 0 1 0 0 U.K.
0 0 0 0 0 1 0 0 Germany
0 0 1 1 1 1 0 1 France
0 0 0 0 1 0 0 1 Australia
1 0 0 1 1 1 0 0 Singapore
0 1 1 0 1 1 0 0 Malaysia
0 1 0 1 0 0 0 0 Hong  Kong
1 1 1 1 1 1 1 0 Taiwan
1 0 1 0 1 0 0 1 Thailand
1 1 1 1 1 1 0 1 Middle  East
0 1 0 1 0 0 1 1 India
1 0 1 0 0 1 0 1 Sweden
0 1 1 1 1 1 1 0 New  Zealand
1 0 1 0 0 0 0 0 Spain
1 0 0 0 1 0 1 1 Portugal
0 1 0 1 1 0 0 1 Italy
1 0 1 0 0 1 1 0 Switzerland
Bit No.
Setting value
1 2 3 4 5 6 7 8
0 0 1 1 1 1 0 0 Finland
0 0 1 1 0 0 0 1 Denmark
1 0 0 0 0 0 1 0 Norway
0 1 1 1 1 0 1 1 Netherlands
0 1 1 0 1 0 0 1 Luxembourg
0 0 0 0 1 1 1 1 Belgium
1 1 1 1 1 0 1 1 Other  3
0 0 0 1 0 1 1 0 Brazil
1 0 0 1 1 1 1 1 South  Africa
0 0 1 0 1 1 1 0 Czech
1 1 1 1 1 1 0 0 Slovakia
0 1 0 1 0 0 0 1 Hungary
0 1 0 0 0 1 1 0 Greece
1 0 0 0 1 0 1 0 Poland
1 0 1 1 1 0 0 0 Russia
0 0 0 0 1 0 1 0 Austria
0 1 0 1 0 1 0 0 Indonesia
1 0 0 0 1 0 0 1 Philippines
1
All area
0
256 byte
Page of 80