MX-RP19. Service Manual for RP19N. - Sharp Copying Equipment Service Manual (repair manual). Page 7

Read Sharp MX-RP19 Service Manual online

MX-RP19 N  ADJUSTMENTS  4 – 2
10) Loosen the CCD unit fixing screws.
Never loosen the screws marked with X.
If any one of these screws is loosened, the position and the
angle  of  the  CCD  unit  base  may  be  changed  to  cause  a
problem,  which  cannot  be  adjusted  in  the  market.  In  that
case, the whole scanner unit must be replaced.
11) Slide the CCD unit in the arrow direction (CCD sub scanning
direction) to change the installing position.
When the copy image is longer than the original scale, shift the
CCD unit  in  the  direction B.  When the copy image  is  shorter
than the original scale, shift the CCD unit in the direction A.
One scale of mark-off line corresponds to 0.2%.
At  that  time,  fix  the  CCD  unit  so  that  it  is  in  parallel  with  the
scale on the front and the rear side of the CCD unit base.
* Fix the CCD unit so that it is in parallel with the line marked
in procedure 9).
12) Make a copy and check the copy magnification ratio again.
If  the  copy  magnification  ratio  is  not  in  the  range  of  100  +/-
0.8%,  repeat  the  procedures  of  9)  -  11)  until  the  condition  is
satisfied.
NOTE: By  changing  the  CCD  unit  fixing position with  the  simula-
tion  48-1  adjustment  value  at  50,  the  copy  magnification
ratio is adjusted within the specified range (100 +/- 0.8%)
and the specified resolution is obtained based on the opti-
cal system structure.
2.  Main scanning direction image 
magnification ratio adjustment (RSPF 
mode)
This adjustment must be performed in the following cases:
* When the scan control PWB is replaced.
* When the EEPROM on the scan control PWB is replaced.
* When U2 trouble occurs.
* When the copy magnification ratio is not matched.
* When the DSPF/RSPF is disassembled.
a. Adjustment procedures
1)
Place the duplex adjustment chart shown below on the docu-
ment  tray  of  the  DSPF/RSPF.  The  adjustment  chart  is  pre-
pared by the following procedures. Use A4 (11" x 8.5") paper,
and put marks on both sides and both surfaces of the paper at
10mm from each edge.
2)
Make a duplex copy at the normal ratio on A4 paper.
3)
Measure  the  images  on  the  copy  paper  and  the  original
images.
4)
Obtain the image magnification ratio according to the following
formula:
Image magnification ratio = Original size / Original size x 100
(%)
Image magnification ratio = 99 / 100 x 100 = 99 (%)
If  the  image  magnification  ratio  is  within  the  specified  range
(100 +/- 0.8%), there is no need to perform the adjustment.
If it is not within the specified range, perform the following pro-
cedures.
A
B
A4 size
(Both the front surface 
and the back surface)
10mm
10mm
Paper pass direction
original
10
50
100
150
200
250
copy
10
50
100
150
200
250
Page of 24
Display