MX-RB20 (serv.man6). Countermeasure for reverse gate of interface unit not returning properly. (MX-RB20) - Sharp Copying Equipment Technical Bulletin (repair manual). Page 2

Read Sharp MX-RB20 (serv.man6) Technical Bulletin online

 
Sharp Electronics (UK) Ltd., Document Systems Support
 
 
2/3 
 
 
1. Remove Interface unit from the main unit of the machine. 
 
 
 
 
 
 
 
 
 
 
 
 
 
2. From the upper and lower side indicated by arrows, check that the grease (FLOIL G313S)   
 
    UKOG-0307FCZZ is applied to the inner/outer side of the spring.    If not applied, please apply it. 
 
 
 
 
 
 
 
 
 
 
 
3. Remove E-ring and sintered bearing at the rear side. 
 
 
 
 
 
 
 
 
 
 
Upper side 
Lower side 
Check the grease on upper side. 
Remove E-ring. 
Remove sintered bearing. 
Check the grease on lower side. 
 
Page of 3
Display