MX-M950, MX-MM1100 (serv.man39). Section 8 Self Diagnostics Trouble Codes - Sharp Copying Equipment Service Manual (repair manual). Page 27

Read Sharp MX-M950 / MX-MM1100 (serv.man39) Service Manual online

MX-M1100 SELF DIAG AND TROUBLE CODE  8 – 27
 
L4-50
Process cooling fan 1 trouble
 
L4-51
Process cooling fan 2 trouble
 
L4-52
Process cooling fan 3 trouble
 
L4-53
Process cooling fan 4 trouble
 
L4-54
PS cooling fan trouble
 
L4-55
Process cooling fan trouble
 
L6-10
Polygon motor trouble
 
L8-01
NO full wave signal 
 
L8-05
No full wave signal (PCU detection)
Detail
The lock signal is detected during operation of the 
process cooling fan
Section
PCU
Cause
Harness connection trouble between the PCU PWB and 
the fan motor.
PCU PWB trouble. Fan motor trouble.
The fan is not rotating due to other trouble. 
(Power is not supplied to the fan motor.)
Check & 
Remedy
Use Sim. 6-2 to check the operation of the fan motor. 
Check the harness and the connector between the PCU 
PWB and the fan motor.
Replace the PCU PWB. Replace the fan motor. 
Detail
The lock signal is detected during operation of the 
process cooling fan
Section
PCU
Cause
Harness connection trouble between the PCU PWB and 
the fan motor.
PCU PWB trouble. Fan motor trouble.
The fan is not rotating due to other trouble. 
(Power is not supplied to the fan motor.)
Check & 
Remedy
Use Sim. 6-2 to check the operation of the fan motor. 
Check the harness and the connector between the PCU 
PWB and the fan motor.
Replace the PCU PWB. Replace the fan motor. 
Detail
The lock signal is detected during operation of the 
process cooling fan
Section
PCU
Cause
Harness connection trouble between the PCU PWB and 
the fan motor.
PCU PWB trouble. Fan motor trouble.
The fan is not rotating due to other trouble. 
(Power is not supplied to the fan motor.)
Check & 
Remedy
Use Sim. 6-2 to check the operation of the fan motor. 
Check the harness and the connector between the PCU 
PWB and the fan motor.
Replace the PCU PWB. Replace the fan motor. 
Detail
The lock signal is detected during operation of the 
process cooling fan
Section
PCU
Cause
Harness connection trouble between the PCU PWB and 
the fan motor.
PCU PWB trouble. Fan motor trouble.
The fan is not rotating due to other trouble. 
(Power is not supplied to the fan motor.)
Check & 
Remedy
Use Sim. 6-2 to check the operation of the fan motor. 
Check the harness and the connector between the PCU 
PWB and the fan motor.
Replace the PCU PWB. Replace the fan motor. 
Detail
The lock signal is detected during operation of the PS 
cooling fan
Section
PCU
Cause
Harness connection trouble between the PCU PWB and 
the fan motor.
PCU PWB trouble. Fan motor trouble.
The fan is not rotating due to other trouble. 
(Power is not supplied to the fan motor.)
Check & 
Remedy
Use Sim. 6-2 to check the operation of the fan motor. 
Check the harness and the connector between the PCU 
PWB and the fan motor.
Replace the PCU PWB. Replace the fan motor. 
Detail
The lock signal is detected during operation of the 
process cooling fan
Section
PCU
Cause
Harness connection trouble between the PCU PWB and 
the fan motor.
PCU PWB trouble. Fan motor trouble.
The fan is not rotating due to other trouble. 
(Power is not supplied to the fan motor.)
Check & 
Remedy
Use Sim. 6-2 to check the operation of the fan motor. 
Check the harness and the connector between the PCU 
PWB and the fan motor.
Replace the PCU PWB. Replace the fan motor. 
Detail
It is judged that the lock signal of the LSU polygon 
motor is not outputted. 
When the lock signal is checked 7sec after starting the 
polygon motor rotation, it is judged that the polygon 
motor does not rotate normally. 
Section
PCU
Cause
Disconnection or breakage of the LSU connector or the 
harness inside the LSU. 
Polygon motor trouble. LSU PWB trouble.
Check & 
Remedy
Check the polygon motor operation with Sim. 61-1.
Check connection of the harness and the connector. 
If the trouble still remains, replace the LSUcnt PWB or 
replace the LSU PWB. 
Detail
No full wave signal is detected
Section
ICU / P-CON
Cause
PCU PWB trouble. 
Power unit trouble. 
Harness trouble. 
Check & 
Remedy
Replace the PCU PWB. Replace the power unit. 
Check connection of the connector and the harness. 
Detail
The full wave signal is not detected (PCU detection)
Section
PCU
Cause
Disconnection or breakage of the connector to the PCU 
PWB or the harness in the power unit.
PCU PWB trouble. Power unit trouble.
Check & 
Remedy
Check connection of the harness and the connector. 
Replace the PCU PWB. Replace the power unit. 