28
5 Layout of the 10-key Pad
1) The 10-key pad used for the machined adjustment
consists of the numeric keys from 0 to 9, the [C] and
[OK] keys and the numerical display.
2) The numeric keys on the 10-key pad are arranged in
the ascending order starting from the top left. The order
cannot be changed.
5.1
Location of the 10-key Pad in the Screen
The 10-key pad appears when each of the textboxes in the
screen is tapped.
5.2
Behavior Specifications of the 10-key
Pad
The behavior specifications of the 10-key pad are as
follows:
When the 10-key pad is opened, the numerical
display shows by default the value currently shown in
the textbox or the factory default value.
A new entry made with the numeric keys of 0 to 9
overwrites a value currently shown in the numerical
display.
The 10-key pad is closed by tapping the [OK] key.
When the 10-key pad is closed, the value in the
numerical display is reflected in the textbox. Any
value that is more than the range is not accepted; a
beep sounds to alert accordingly when a numeric key
that results in such value is tapped. When the value in
the numerical display is less than the range, the [OK]
key becomes inactive.
The value in the numerical display is cleared by
tapping the [C] key. When the [OK] key is tapped just
after the numerical display is cleared, the entry is
canceled and not reflected in the textbox; the original
value or the factory default value remains effective.
The [Cancel] and [Back] keys in each setting screen
are active while the 10-key pad is being displayed.
When the [Cancel] or [Back] key in the screen is
tapped, the ongoing entry on the 10-key pad is
canceled and the 10-key pad is closed and then the
screen returns to the previous one. The [Register],
[Execute] and [Return to the Defaults] keys in each
setting screen, however, are not active while the
10-key pad is being displayed.
Click on the first or last page to see other MX-M905 (serv.man7) service manuals if exist.