MX-M850 (serv.man38). Section 8 Self Diagnostics Trouble Codes - Sharp Copying Equipment Service Manual (repair manual). Page 6

Read Sharp MX-M850 (serv.man38) Service Manual online

MX-M1100 SELF DIAG AND TROUBLE CODE  8 – 6
F1
46
Rear edge fence shift motor trouble 
(finisher + saddle unit + inserter) 
Rear edge fence motor trouble  (saddle finisher)
PCU
47
Drive collar oscillation motor trouble
PCU
48
Saddle discharge motor trouble
PCU
50
Finisher incompatible trouble
PCU
60
Communication trouble between peripheral devices 
(inserter detection)
PCU
64
No. 1 pickup motor trouble
PCU
65
No. 2 pickup motor trouble
PCU
66
No. 1 lift motor trouble  
(finisher + saddle unit + inserter) 
Lift motor 1 trouble (booklet maker)
PCU
67
No. 2 lift motor trouble  
(finisher + saddle unit + inserter) 
Lift motor 2 trouble (booklet maker)
PCU
70
Communication trouble between peripheral devices  
(Z-folding machine detection)
PCU
71
Varistor abnormality
PCU
72
Z-folding machine EEPROM abnormality
PCU
73
Separation sensor adjustment abnormality
PCU
74
Pressure sensor adjustment abnormality
PCU
75
Upper stopper motor trouble
PCU
76
Lower stopper motor trouble
PCU
77
Folding motor trouble
PCU
83
Lead edge stopper motor trouble
PCU
84
Movable fence motor trouble
PCU
85
Return transport motor trouble
PCU
86
Return drive motor trouble 
(finisher + saddle unit + inserter) 
Return roller oscillation motor trouble 
(saddle finisher)
PCU
87
Shift jogger motor trouble
PCU
88
Shift jogger retract motor trouble
PCU
89
Shift motor trouble
PCU
F2
00
Toner control sensor open
PCU
02
Toner supply abnormality
PCU
04
An improper toner cartridge is detected. 
PCU
05
Toner cartridge CRUM error
PCU
06
CRUMID error
PCU
F2
31
Process control trouble (OPC drum surface 
reflection rate abnormality)
PCU
33
Surface potential sensor abnormality trouble
PCU
39
Process thermistor breakdown
PCU
47
Room temperature thermistor breakdown
PCU
58
Process humidity sensor breakdown
PCU
59
Room humidity thermistor trouble
PCU
F3
12
Machine cassette 1 lift-up trouble
PCU
22
Machine cassette 2 lift-up trouble
PCU
32
Machine cassette 3 lift-up trouble
PCU
42
Machine cassette 4 lift-up trouble
PCU
F4
38
38 (V) voltage trouble
PCU
F5
10
Lamp thermistor open detection trouble (SCU 
detection)
SCU
12
Lamp thermistor abnormality detection (SCU 
detection)
SCU
F6
00
Communication trouble between the MFP and the 
FAX (MFP detection)
ICU
01
FAX PWB EEPROM read / write error
ICU / FAX
04
FAX MODEM operation abnormality
ICU / FAX
21
Combination error of the TEL / LIU PWB and the 
FAX soft switch
ICU / FAX
30
Access error to the power controller on the FAX 
PWB. (FAX detection)
ICU / FAX
97
FAX PWB skating trouble. The FAX PWB model 
identification does not match the machine model. 
ICU
98
Combination error between the FAX PWB 
destination information and the machine destination 
information
ICU
F9
00
Communication trouble between the controller and 
the printer controller (FIERY).
ICU
Trouble code
Trouble code content
Remarks
Trouble
detection
Mechanism
Option
Electricity
FAX
Supply
Main
code
Sub
code
Page of 33
Display

Click on the first or last page to see other MX-M850 (serv.man38) service manuals if exist.