52
Used to set whether non-print paper (insertion, cover sheet) is counted or not.
Setting
69
Used to set preliminary preparation of toner and near end display when the toner quantity
reaches 25%.
reaches 25%.
Setting
27
1
Used to set non-detection of the communication error (U7-00) with RIC.
Setting
2
Used to set the FSS function (user registration number, Host server telephone number).
Setting
4
Used to set the FSS function (initializing, call, toner order auto send).
Setting
5
Used to set the machine tag No.
(This simulation allows to check the machine tag No. from the host computer side.)
(This simulation allows to check the machine tag No. from the host computer side.)
Communication
(RIC/MODEM)
(RIC/MODEM)
Setting
6
Used to set the FSS function (manual service call).
Setting
7
Used to set the FSS function (enable, Alert calling)
Setting
9
Used to set the paper transport time between sensors and the gain adjustment retry number.
Setting
10
Used to clear the trouble prognosis history information.
Data clear
11
Used to check the serial communication retry number history and the scanner GAIN adjustment
retry number history.
retry number history.
Other
12
Used to check the error history of high density, half-tone potential, and dark potential.
Other
13
Used to check the history of paper transport time between sensors.
Other
14
Used to set the FSS function connection mode. (Enable only for Disable to Enable)
Setting
30
1
Used to check the operation of the sensors and the detectors in other than the paper feed section
and the control circuits.
and the control circuits.
Operation test/check
2
Used to check the operation of the sensors and the detectors in the paper feed section and the
control circuits.
control circuits.
Operation test/check
10
Used to check the Main unit double feed detection sensor (Paper feed)
(Must not be used
unless a special
change is required.)
unless a special
change is required.)
33
1
Used to check the operation of the sensors in the card reader and the control circuit.
Operation test/check
2
The card ID (IDM) information supporting the Felica card in the machine user registration
information is deleted.
information is deleted.
Data clear
40
2
Used to adjust the detection level of the manual paper feed tray paper width detector.
Paper feed
Adjustment/ Setting
7
Used to adjust the manual paper feed tray size width detection level.
Paper feed
Adjustment/ Setting
12
Used to adjust the tray 4 width detection level.
Paper feed
Adjustment/ Setting
41
1
Used to check the operation of the document size sensor and the control circuit.
Operation test/check
2
Used to adjust the document size sensor detection level.
Adjustment
3
Used to check the operation of the document size sensor and the control circuit.
Operation test/check
43
1
Used to set the fusing temperature of each paper mode.
Setting
31
Used to check the operation of the fusing web cleaning motor and the control circuit.
Operation test/check
32
Used to set the forcible operation of the fusing web cleaning when job end.
Adjustment/ Setting
33
Used to make setting of before-fusing PG operations.
Setting
44
1
Used to set each correction function of the image forming (process) section.
Process (OPC
drum, developing,
transfer, cleaning)
drum, developing,
transfer, cleaning)
Setting
2
Used to adjust the process control sensor gain.
Process
Adjustment/ Setting
3
A change in the OPC drum surface potential VO due to the OPC drum environment and
membrane decrease (life) is detected with the surface potential sensor to correct the grid
potential Vg so that the cleaning field is maintained at a constant level.
membrane decrease (life) is detected with the surface potential sensor to correct the grid
potential Vg so that the cleaning field is maintained at a constant level.
Process
Operation test/check
4
Used to set the operating conditions of the high density process control.
(Must not be used
unless a special
change is required.)
unless a special
change is required.)
5
Used to set the dark potential adjustment conditions.
Adjustment/ Setting
6
Used to perform forcible execution of the high density process correction.
Adjustment
7
Used to clear the high density process control correction data.
Data clear
9
Used to display the process data.
Process (OPC
drum, developing,
transfer, cleaning)
drum, developing,
transfer, cleaning)
(This simulation is
normally not used in
the market.)
normally not used in
the market.)
12
Used to display the result of the high density process control.
Process (OPC
drum, development)
drum, development)
(This simulation is
normally not used in
the market.)
normally not used in
the market.)
14
Used to check the output levels of the fusing temperature sensor, the machine temperature
sensor, and the humidity sensor.
sensor, and the humidity sensor.
Process (OPC
drum, development)
drum, development)
Adjustment/ Setting/
Operation data check
Operation data check
16
Used to check the toner density control data.
(This simulation is
normally not used in
the market.)
normally not used in
the market.)
28
Used to set the process control execution timing.
Adjustment/ Setting
33
Used to perform forcible execution of the half-tone potential adjustment.
Adjustment/ Setting
34
Used to correct the half tone potential changing caused by dark decrease variation made by
membrane decrease (life) / temperature characteristics of the OPC drum.
membrane decrease (life) / temperature characteristics of the OPC drum.
35
Used to display the half-tone potential adjustment result.
36
Used to clear the half-tone potential adjustment correction quantity.
Data clear
46
2
Used to adjust the copy density adjustment in the copy mode.
Adjustment
(B/W copy mode)
(B/W copy mode)
4
Used to adjust the density in the scanner mode.
Adjustment
(Color scanner mode)
(Color scanner mode)
5
Used to adjust the density in the scanner mode.
Adjustment
(Monochrome
scanner mode)
(Monochrome
scanner mode)
Main
Sub
Function (Purpose)
Section
Purpose