MX-M850 (serv.man37). Section 7 Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 19

Read Sharp MX-M850 (serv.man37) Service Manual online

MX-M1100  SIMULATION  7 – 19
 
7-6
Purpose
Setting
Function (Purpose) Used to set the intermittent aging cycle.
Section
Operation/Procedure
1)
Enter the intermittent aging cycle (unit: sec) with 10-key.
2)
Press [OK] key.
The time set in step 1 is set.
* The setting range of the interval time is 1 - 900 (sec).
3)
When [SYSTEM SETTINGS] key is pressed, the screen
returns to the SUB code entry menu.
 
7-8
Purpose
Operation display
Function (Purpose) Used to display the warm-up time.
Section
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Counting of the warm-up time is started.
* Interruption during the execution with [EXECUTE] key is
invalid.
 
7-12
Purpose
Operation test, check
Function (Purpose) Used to set the document scan quantity.
(For development and inspection)
Section
Operation/Procedure
1)
Enter the set value with 10-key.
2)
Press [OK] key, and the currently set data are saved to the
EPROM and the RAM.
3)
When [SYSTEM SETTINGS] key is pressed, the screen
returns to the sub code entry menu. 
 
8
 
8-1
Purpose
Operation test/check/adjustment
Function (Purpose) Used to check and adjust the developing
voltage in each print mode and the control
circuit.
Section
Process (Development)
Operation/Procedure
1)
Select a target item of the adjustment with [
↑] [↓] keys.
2)
Enter the set value with 10-key.
* When U or V key is pressed, the set value of each item is
increased or decreased by 1.
Collective change can be made.
3)
Press [EXECUTE] key.
The currently set voltage is outputted and the set value is
saved.
4)
When [SYSTEM SETTINGS] key is pressed, the screen
returns to the SUB code entry menu.
 
8-2
Purpose
Operation test/check/adjustment
Function (Purpose) Used to check and adjust the operations of
the main charger grid voltage in each print
mode and the control circuit.
Section
Process
Operation/Procedure
1)
Select a target item of the adjustment with [
↑] [↓] keys.
2)
Enter the set value with 10-key.
* When U or V key is pressed, the set value of each item is
increased or decreased by 1.
Collective change can be made.
3)
Press [EXECUTE] key.
The currently set voltage is outputted and the set value is
saved.
4)
When [SYSTEM SETTINGS] key is pressed, the screen
returns to the SUB code entry menu.
Item
Display
Content
Setting 
range
Default 
value
A
ORIGINALS
Document scan quantity 
setting (for aging)
0 - 999
0
Item/Display
Content
Setting range
Default
Monitor connector
Actual output 
voltage
Connector
Pin No.
A
COPY
Developing bias adjustment value (Copy mode)
0-750
495
CN2
7
-500 
± 1 V
B
PRINTER
Developing bias adjustment value (Printer mode)
0-750
495
CN2
7
-500 
± 1 V
C
FAX
Developing bias adjustment value (FAX mode)
0-750
495
CN2
7
-500 
± 1 V
D
PLUS
Reverse developing bias voltage
0-250
150
CN2
7
-500 
± 1 V
Page of 103
Display