MX-M850 (serv.man33). Section 2 Specifications - Sharp Copying Equipment Service Manual (repair manual). Page 9

Read Sharp MX-M850 (serv.man33) Service Manual online

MX-M1100  SPECIFICATIONS  2 – 9
L. Power cord list
* PS: Power supply
AC Voltage Check (For USA / CANADA)
When installing this machine (MX-M1100 / 950 / 850), please confirm the actual voltage at the place of installation by the following method
and take action as below according to the voltage. Please notify the customer that they need to prepare a new power supply line if the
breaker capacity is insufficient for 20A load.
(Measurement method)
Measure the voltage between L and N of the figure above using a digital multi meter.
1)
When the measured voltage is 208V - 218V (208V + 5%)
The fusing performance may become insufficient depending on the environment of installation and the paper.
If the fusing performance is insufficient when using thick paper and so on, it is recommended to use the heater lamp for 208V
(RLMPU0764FCPZ), which is a service part.
2)
When the measured voltage is less than 208V
Please replace the heater lamp with the heater lamp for 208V (RLMPU0764FCPZ), which is a service part, at installation.
(NOTE)
Do not use the heater lamp for 208V above for 240V voltage. (The life of the heater lamp becomes shorter.)
85-sheet machine
95/110-sheet machine
USA / 
CANADA
P
S
Shape of PLUG
15A
208V - 240V
20A
PS for
option
Wiring/Breaker capacity
(Machine rating)
L
N
GND
V
Voltage reference points for wall outlet.
Page of 10