MX-M623U, MX-M753U (serv.man7). INSTALLATION MANUAL. - Sharp Copying Equipment Service Manual (repair manual). Page 13

Read Sharp MX-M623U / MX-M753U (serv.man7) Service Manual online

MX-M753N  MX-M623N/M623U/M753N/M753U  1 – 9
G. Cleaning
(1) Main charger
1)
Reciprocate the MC cleaner shaft back and forth to clean the
electrode tip.
H. Specifications setup
Used to set the specifications with SIM26 according to the cus-
tomer's request.
To customize the following items after completion of the destination
setup, change the set values.
I. Image quality check
(1) Copy density and gradation check
NOTE: Before checking the copy density and gradation, be sure to
execute the following jobs.
* Execute the high density image correction (Process correction)
forcibly. (SIM 44-6)
* Execute the half-tone image correction forcibly. (SIM 44-26)
(Method)
Make a copy of the gray test chart (UKOG-0162FCZZ), and check
that it is proper.
Note for checking the copy mode density
To check the density, use the gray test chart (UKOG-0162FCZZ).
Set the copy density level to “Manual 3” in the Text/Printed Photo
mode (Manual).
In addition, all the picture quality adjustment settings in the user
adjustment mode must be set to the default (center).
[Check with the gray test chart (UKOG-0162FCZZ)]
In the copy density check with the gray test chart, check to insure
the following conditions.
[Check with the servicing color test chart (UKOG-0317FCZZ/
UKOG-0317FC11 or UKOG-0326FCZZ/UKOG-0326FC11)]
Check to confirm that it is in the conditions shown below.
(2) Printer density and gradation check
If no printer option is installed to the U model, the following proce-
dures are not required. (SIM64-5 does not operate.)
NOTE: Before checking the printer density and gradation, be sure
to execute the following jobs.
* Execute the high density image correction (Process correction)
forcibly. (SIM 44-6)
* Execute the half-tone image correction forcibly. (SIM 44-26)
(Method 1)
Execute SIM 64-5 to print the print test pattern.
Set each set value to the default and press [EXECUTE] key. The
print test pattern is printed.
The print density must be changed gradually from the lighter level
to the darker level. The density changing direction must not be
reversed.
SIM No
Content
26
6
Used to set the destination.
SIM No
Content
26
2
LCC paper size setting
3
Used to set the auditor specification mode.
5
Used to set the count mode of the total counter and the 
maintenance counter.
18
Used to set YES/NO of the toner save mode 
(Only in UK and Japan versions)
* For other destination versions, this setup is made by 
the user program.
52
Used to set YES/NO of counting when non-print paper 
is passed through each counter.
53
Used to set YES/NO of user calibration permission.
65
Used to set the limit number of sheets for stapling.
1
2
3
4
5
6
7
8
9
10
W
SHARP GRAY CHART
SHARP gray chart
Patch 1 is not copied.
Patch 2 is
slightly copied.
Patch 3 is copied.
Serviceman chart (Color patch section)
Patch 7 is slightly
copied or not copied.
Page of 104