MX-M364N, MX-565N (serv.man37). COUNTERMEASURE FOR CONTAMINATION ON PAPER EDGE AND PROCESS CONTROL DENSITY SENSOR ADJUSTMENT TROUBLE (F2-78) - Sharp Copying Equipment Technical Bulletin (repair manual). Page 2

Read Sharp MX-M364N / MX-565N (serv.man37) Technical Bulletin online

 
 
 
Sharp Electronics (UK) Ltd., Technical Services Group
 
 
 
 
 
 
2. 
Installation procedure pf Process sensor cover sheet 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fold the sheet along the slit at a 
90-degree angle so that the 
double-faced tape section is 
facing inwards. 
Fold the sheet along the 
slit. 
After folding, remove all back 
sheets. 
<NOTE> Clean the sensor lens 
surface with air or dry cloth to 
remove foreign materials like 
toner, etc. 
 
Insert the sheet from the top up to the 
place surface while adjusting the folding 
line of the sheet and the angle of the 
sensor. 
 
Check that the attached surfaced is not 
lifted. 
Attach the sheet while tightly 
holding the red section in the 
picture. 
Attach the sheet while tightly 
holding the red section in the 
picture.  After attaching the 
sheet, check that the sheet 
does not run off the plate. 
 
Process control 
sensor PWB 
① 
② 
③ 
④ 
⑤ 
Page of 3
Display