1. Open the upper cover.
2. Remove the upper cover stay
Open the upper guide more than 90-degree
Unfasten the screws (x 2) and remove the upper cover stay.
while pushing it forward.
Springs that should be replaced.
3. Replace the springs.
Springs for countermeasure (x 2)
(3-1) Remove the current springs.
(3-2) Mount the springs for countermeasure.
1/2
FN10 Spring Replacement Procedure
Lower hook
Upper hook
Section where to hook.
(The plate springs of the rear side are fastened
together. When removing the upper cover stay
please be careful not to drop the plate springs.)
together. When removing the upper cover stay
please be careful not to drop the plate springs.)
Unhook the lower hook of the spring that is mounted.
Then pull the upper hook from the shaft and take it off.
Dispose of the removed springs.
Then pull the upper hook from the shaft and take it off.
Dispose of the removed springs.
Hook the lower hook.