Read Sharp MX-M232D (serv.man32) Technical Bulletin online
Sharp Electronics (UK) Ltd., Document Systems Support
3/3
(For
618/5618D/5618N/5618S/5620/5620D/5620N/5620S/5623/5623D/5623DA/5623N
AR-5620SL/5620SLX, AR-X180/X180S/X200/X200D/X230N,
MX-M182/M182D/M202D/M232D, MX-M181D/M211D, MX-M160/M160D/M200D,
AR-5516/5516X/5516S/5516SX/5516D/5516DX/5516N/5516NX
AR-5520/5520X/5520S/5520SX/5520D/5520DX/5520N/5520NX, AR-5518)
Note1) Set the hooks of DV-BOX to the squire holes of the cartridge guide AS.
Note2) Install the cartridge guide AS while rotating.
Note3) Make sure that DV blade does not get caught.
Check the hooks of DV-BOX from the
upper holes of the cartridge guide AS.
(1)
Set the hooks of DV-BOX to the
squire holes of the cartridge
guide AS (2-position)
(2)
Rotate the cartridge guide AS based on
the hooks which have been set as the
fulcrum point, and then insert the positioning
boss of the DV-BOX into the positioning
holes of the cartridge guide AS.
(3)
After installing the cartridge
guide AS, make sure that DV
blade does not get caught.
(both of front/rear side)