MX-M202D (serv.man24). SERVICE PARTS SETTINGS AND MOUNTING PROCEDURE - Sharp Copying Equipment Technical Bulletin (repair manual). Page 2

Read Sharp MX-M202D (serv.man24) Technical Bulletin online

 
Sharp Electronics (UK) Ltd., Document Systems Support
 
 
2/5 
     
CV_AUD I/F Service Parts Mounting Procedure   
     1. Model Name: MX-M182/M182D/M202D/M232D 
   
 
AR-5618/5618D/5618N/5620/5620D/5620N/5623/5623D/5623N 
   
 
AR-X180/X200/X200D/X230N 
 
 
(1) Remove the rear cabinet from the main unit. 
 
 
(2) Fix the CV_AUD I/F PWB at the location shown on the photo below with screws. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
* If only one of Coin Vendor and Auditor is used, it is all right with the unused side disconnected 
 
 
  For connection to 
 Auditor * 
  For connection to 
 MCU PWB 
  For connection to 
  Coin Vendor * 
  Location for CV_AUD I/F 
  PWB UNIT to be fixed 
Tighten it at these 2 locations with screws. 
Page of 5
Display