Read Sharp MX-M182 / MX-M182D (serv.man25) Technical Bulletin online
Sharp Electronics (UK) Ltd., Document Systems Support
2/5
CV_AUD I/F Service Parts Mounting Procedure
1. Model Name: MX-M182/M182D/M202D/M232D
AR-5618/5618D/5618N/5620/5620D/5620N/5623/5623D/5623N
AR-X180/X200/X200D/X230N
(1) Remove the rear cabinet from the main unit.
(2) Fix the CV_AUD I/F PWB at the location shown on the photo below with screws.
* If only one of Coin Vendor and Auditor is used, it is all right with the unused side disconnected
For connection to
Auditor *
For connection to
MCU PWB
For connection to
Coin Vendor *
Location for CV_AUD I/F
PWB UNIT to be fixed
Tighten it at these 2 locations with screws.