MX-M160, MX-M160D, MX-M160DK (serv.man2). Service Manual. - Sharp Copying Equipment Service Manual (repair manual). Page 22

Read Sharp MX-M160 / MX-M160D / MX-M160DK (serv.man2) Service Manual online

MX-M200D ADJUSTMENT 6-2
(3)Developing bias voltage check
Note:Use a digital multi-meter with an internal resistance of 10M
Ω or 
more.
1) Set the digital multi-meter range above 500 Vdc. 
2) Put the test rod of the digital multi-meter on the developing bias 
voltage output check pin. 
3) Turn on the power, execute SIM25-1.
<Specification>
(4) Grid bias voltage check
Note:Use a digital multi-meter with an internal resistance of 10M
Ω or 
more.
1) Set the digital multi-meter range above 600 Vdc.
2) Put the test rod of the digital multi-meter on the grid bias voltage 
output check pin. 
3) Turn on the power. 
 
(The voltage is outputted in the grid bias High output mode during 
warming up, and in the grid bias Low output mode when warming up 
is completed.)
<Specification>
B.Mechanism section
Note: If a jam error or paper empty occurs during copying in the 
adjustment by the simulation, the image data is not saved, and 
therefore recopying is required.
(1) Image position adjustment
a.OC image lead edge position adjustment (SIM 50-1)
Note: In advance to this adjustment, the sub scanning magnification ratio 
adjustment must be performed.
1) Set a scale on the OC table as shown below.
2) Make a copy.
3) Check the copy output. If necessary, perform the following 
adjustment procedures.
4) Execute SIM 50-1.
5) Set the OC lead edge position set value (PHOTO indicator ON) to [1]
 
The OC image scanning start position is shifted inside the document 
edge.
6) Set the 1st tray lead edge void adjustment value (TEXT indicator 
ON) * to [1]
 
The lead edge void becomes the minimum.
7) Set the 1st tray print start position value (AUTO, 1st tray indicator 
ON) to [1] and make a copy.
 
The print start position is shifted inside the document edge.
8) Measure the image loss R of the copied image. Enter the set value of 
the image scanning lead edge position (PHOTO indicator ON) again.
•1 step of the set value corresponds to about 0.1mm shift.
•Calculate the set value from the formula below.
R/0.1(mm) = Image loss set value
 
 <R: Image loss measurement value (mm)>
Example:
4/0.1 = 40 = about 40
Note: If the set value is not obtained from the above formula, perform the 
fine adjustment.
Mode
 Specification
Developing bias voltage
 DC - 400±10V
Mode
 Specification
Grid bias LOW
 DC - 380±8V
Grid bias HIGH
 DC - 525±10V
5
10
5mm
4mm
*
The dimension varies depending on the model.
10
5mm
0mm
5
*
 The scanning edge is set. 
   (A line may be printed by scanning the document edge.)
 