MX-LC13 (serv.man27). IMPROVEMENTS FOR INSTALLING MX-LC13 N - Sharp Copying Equipment Technical Bulletin (repair manual). Page 13

Read Sharp MX-LC13 (serv.man27) Technical Bulletin online

MX-M1204  MX-LC13 (LARGE CAPACITY TRAYS)  8 – 11
4) Joint the LCT connecting plates (F/R) fixed to MX-LC13 and
the connecting plates (F/R) fixed to the main unit.
NOTE: Note for separation
When separating, tighten the screw to release the
lock.
When connecting again, loosen the screw after con-
nection.
5) Ensure even clearance of the upper section by pushing the
MX-LC13.
6)
Connect the connector from MX-LC13 to the machine and
tighten the screw.
NOTE: Use an L-shape screwdriver.
C. When connecting two units
1)
Install the MX-RB17.
2)
Attach the LCT connecting plate to the large capacity trays
with the screws (Packed items No. 4 S-tight, M4 x 8).
MEMO: The reference label is attached to the plate. Attach it
so that the label can be seen from the outside.
3)
Attach the connection plates (F/R) to the first-series MX-LC13
with the screws (Packed items No. 4 S-tight, M4 x 8).