MX-C310, MX-C311, MX-C312, MX-C380, MX-C381, MX-C400, MX-C401 (serv.man125). Revised Service Manual. - Sharp Copying Equipment Service Manual (repair manual). Page 114

Read Sharp MX-C310 / MX-C311 / MX-C312 / MX-C380 / MX-C381 / MX-C400 / MX-C401 (serv.man125) Service Manual online

MX-C401 Functions of the keys used in the simulation mode  5 – 4
(3)
Functions of the keys used in the simulation mode
a. 4.3 Inch LCD model
6, 7, 8,9
2 3
11
10
16
21
4
22 18
1
5
17
13
12
19
14
15
20
No.
Button / Key
Function and purpose in the simulation mode
1
Job status key
Not used in the simulation mode.
2
Document filing mode key
Not used in the simulation mode.
3
Image send mode key
Not used in the simulation mode.
4
Copy mode key
Used to shift from the simulation mode to the normal mode temporarily. (Corresponds to "CLOSE" 
button on the simulation menu of the touch panel system.)
5
System setting key
• Used to shift the menu to the one-step upper stage menu in the simulation mode. 
• Press this key to return from the normal mode (temporarily shifted from the simulation mode) to 
the simulation mode. 
6
Scroll key 
(Cursor key)
UP scroll key (Cursor key)
• Used to scroll upward. (Item selection)
• Used to switch to the next screen. 
7
DOWN scroll key (Cursor key)
• Used to scroll downward. (Item selection)
• Used to switch to the previous screen. 
8
LEFT scroll key (Cursor key)
Used to select a button on the simulation menu. (Left direction)
9
RIGHT scroll key (Cursor key)
Used to select a button on the simulation menu. (Right direction)
10
OK key
Used to settle the selected button or item. 
11
BACK key
Not used.
12
Color start key
• Used to settle the simulation main code and the sub code. 
• Used to start  color copying in the simulation mode. 
13
BW start key
• Used to settle the simulation main code and the sub code. 
• Used to start  monochrome copying in the simulation mode. 
14
Clear all key (CA)
Used to cancel the simulation mode. 
15
Stop key
Not used.
16
Clear key
Used to clear the input value. 
17
10 key
• Used to enter the adjustment value, the set value, and the product key, etc. 
• Used to select an item directly in the simulation mode. 
18
* key (logout)
Used to enter the simulation mode. 
19
P/# key
Used when entering the simulation mode. 
20
Energy save key
Not used in the simulation mode. 
21
Power key
Not used in the simulation mode. 
22
OSA shortcut key
• Used to settle the adjustment value, the set value, the product key, etc. 
• An item is directly selected with the number, and it is settled with this key. 
Page of 127
Display