MX-AP14. Service Manual. - Sharp Copying Equipment Service Manual (repair manual). Page 22

Read Sharp MX-AP14 Service Manual online

MX-AP14  FIRMWARE UPDATE  7 – 1
MX-AP14
Service Manual
 
[7] FIRMWARE UPDATE
1. Outline
A. Cases where update is required
ROM update is required in the following cases:
1)
When there is a necessity to upgrade the performance.
2)
When installing a new spare part ROM for repair to the
machine.
3)
When installing a new spare parts PWB unit (with ROM) for
repair to the machine.
4)
When there is a trouble in the ROM program and it must be
repaired.
B. Items which needs preparations
1)
USB memory.(4GB or more memory capacity)
2)
Firmware.
3)
Store firmware with HDI folder into USB memory
Do not change folder name and contents of each file..
2. Update procedure
1)
Touch [Scan Accessory Kit Settings] key on home screen of
the operation panel.
2)
Enter your password in the admin login screen.
3)
Touch [System Settings] key.
4)
Touch [Update of Firmware] key and touch [Select USB Mem-
ory] after connecting USB memory to the Scan Accessory Kit.
5)
Display file name with extension HDI in the USB memory root
folder. Select and touch [Start] key.
HDI folder composition 
<AP14.01001700.HDI> 
+------ md5.xml 
+------ <hdi> 
  
 
+----- 
version.txt 
  
 
+----- 
approximateTime.txt 
  
 
+----- 
diskpart.txt 
  
 
+----- 
ai.cmd 
  
 
+----- 
<images> 
   
 
+----- 
dat.wim 
   
 
+----- 
win.swm 
   
 
+----- 
win2.swm 
   
 
+----- 
win3.swm 
 
 
 
 
 
Page of 31